Recently, renewable wind energy is enjoying a rapid growth globally to become an important green electricity source to replace polluting and exhausting fossil fuel. However, with wind being an uncontrollable resource and the nature of distributed wind induction generators, integrating a large-scale wind-farm into a power system poses challenges, particularly in a weak power system. In the paper, the impact of STATCOM to facilitate the integration of a large wind farm into a weak power system is studied. First, an actual weak power system with two nearby large wind farms is introduced. Based on the field SCADA data analysis, the power quality issues are highlighted and a centralized STATCOM is proposed to solve them, particularly the short-term (seconds to minutes) voltage fluctuations. Second, a model of the system, wind farm and STATCOM for steady-state and dynamic impact study is presented, and the model is validated by comparing with the actual field data. Using simulated PV and QV curves, voltage control and stability issues are analyzed, and the size and location of STATCOM are assessed. Finally, a STATCOM control strategy for voltage fluctuation suppression is presented and dynamic simulations verify the performance of proposed STATCOM and its control strategy.Index Terms-STATCOM, wind farm, voltage fluctuation, voltage stability, impact study.
Recently, renewable wind energy is enjoying a rapid growth globally to become an important green electricity source to replace polluting and exhausting fossil fuel. However, with wind being an uncontrollable resource and the nature of distributed wind induction generators, integrating a large-scale wind-farm into a power system poses challenges, particularly in a weak power system. In the paper, the impact of static synchronous compensator (STATCOM) to facilitate the integration of a large wind farm (WF) into a weak power system is studied. First, an actual weak power system with two nearby large WFs is introduced. Based on the field SCADA data analysis, the power quality issues are highlighted and a centralized STATCOM is proposed to solve them, particularly the short-term (seconds to minutes) voltage fluctuations. Second, a model of the system, WF, and STATCOM for steady state and dynamic impact study is presented, and the model is validated by comparing with the actual field data. Using simulated PV and QV curves, voltage control and stability issues are analyzed, and the size and location of STATCOM are assessed. Finally, a STATCOM control strategy for voltage fluctuation suppression is presented and dynamic simulations verify the performance of proposed STAT-COM and its control strategy.Index Terms-Impact study, static synchronous compensator (STATCOM), voltage fluctuation, voltage stability, wind farm (WF).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.