Purpose: To compare in vivo emulsification of silicone oil 1000 and 5000 centistokes (cs) after retinal detachment surgery. Design: Comparative non-interventional Retrospective study. Methods: Silicone oils from patients who underwent retinal detachment surgery were investigated using Spectrophotometer UV-Vis. Spectroscopically changes determine emulsification with the time of tamponade, inflammation, patients age and severity of retinal detachment. Results: We found significant difference on absorbance (p = 0.004) between used 1000 Centi stoke (cs) silicon oil (average wave length 2.51 nm; SD: 1.575 nm) and used 5000 cs silicon oil (average wave length 0.910 nm; SD: 0.564 nm). Conclusions: In vivo emulsification was higher in silicone oil 1000 compared to 5000 cs silicone oil after vitreoretinal tamponade 8 -12 weeks due to retinal detachment surgery. Emulsification related to higher absorbance and lower transmittance in 1000 cs silicone oil. Inflammation may become a factor affecting this condition.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.