Informationen über mögliche Inhibitionsstrategien und Mannosidsynthesen liefert eine Konformationsanalyse der enzymatischen Mannosidhydrolyse. Strukturen in atomarer Auflösung entlang der Reaktionskoordinate machen deutlich, wie eine invertierende α‐Mannosidase ihr Substrat und den Übergangszustand verzerrt. QM/MM‐Rechnungen zeigen die Verformung der Freie‐Energie‐Fläche von isolierter α‐D‐Mannose bei der enzymatischen Umsetzung, für die nur ein konformativer Reaktionsverlauf möglich wird.
Prosthodontic maintenance was restricted to loss of retention for all systems. Within the observation period of this study, the self-aligning attachment system showed a higher rate of maintenance than the ball attachments. The patients' oral health-related life qualities as well as the biologic parameters do not differ when using the three abutment systems.
Background: The use of endosseous dental implants has become common practice for the rehabilitation of edentulous patients, and a two-implant overdenture has been recommended as the standard of care. The use of small-diameter implants may extend treatment options and reduce the necessity for bone augmentation. However, the mechanical strength of titanium is limited, so titanium alloys with greater tensile and fatigue strength may be preferable.
The potential use of autologous thrombocytic growth factors to accelerate bone regeneration requires improved methods of isolating platelet-rich plasma (PRP). In addition to discontinuous cell separation, a second method by which PRP is produced at the point-of-care has now become available. In this study, growth factor levels in PRP from these two sources were compared. Whole blood was drawn from 115 healthy donors (73 males, 42 females) aged 21 - 62 years (mean 36, SD 10). The PRP was separated by the blood bank (BB) using the discontinuous cell separation method or at the 'point-of-care' by the so-called 'buffy coat' method (analogous to the Curasan PRP Kit). Growth factor content differed significantly for TGF-beta1 (BB 268.65+/-70.77 ng/ml, Curasan 95.02+/-60.67 ng/ml (sign test P<0.001)) and PDGF-AB (BB 133.59+/-46.26 ng/ml, Curasan 233.70+/-111.86 ng/ml (P<0.001)), while the content of IGF-I (BB 85.37+/-25.58 ng/ml, Curasan 101.72+/-47.7 ng/ml (P<0.160)) showed no significant difference. The higher thrombocyte count in the BB PRP (BB 1434300+/-351960/ microl, Curasan 908.500+/-492.30/microl) seems to result in higher TGF-beta1 levels, while the higher leukocyte count in the Curasan PRP (BB 160+/-320/ microl, Curasan 30130+/-12500/microl) seems to result in higher PDGF-AB levels. The similar IGF-I levels in the two preparations might merely reflect similar amounts of plasma in the PRP produced by each approach.
BackgroundThe augmentation of the jaw has been and continues to be a sophisticated therapy in implantology. Modern CAD-CAM technologies lead to revival of old and established augmentation techniques such as the use of titanium mesh (TM) for bone augmentation. The aim of this retrospective study was to evaluate the clinical outcome of an individualized CAD-CAM-produced TM based on the CT/DVT-DICOM data of the patients for the first time.MethodsIn 17 patients, 21 different regions were augmented with an individualized CAD-CAM-produced TM (Yxoss CBR®, Filderstadt, Germany). For the augmentation, a mixture of autologous bone and deproteinized bovine bone mineral (DBBM) or autologous bone alone was used. Reentry with explantation of the TM and simultaneous implantation of 44 implants were performed after 6 months. Preoperative and 6-month postoperative cone beam computed tomographies (CBCT) were performed to measure the gained bone height.ResultsThe success rate for the bone grafting procedure was 100%. Thirty-three percent of cases presented an exposure of the TM during the healing period. However, premature removal of these exposed meshes was not necessary. Exposure rate in augmentations performed with mid-crestal incisions was higher than in augmentations performed with a modified poncho incision (45.5 vs. 20%, p = 0.221). In addition, exposure rates in the maxilla were significantly higher than in the mandible (66.7 vs. 8.3%, p = 0.009). Gender, smoking, periodontal disease, gingiva type, used augmentation material, and used membrane had no significant influence on the exposure rate (p > 0.05). The mean vertical augmentation was 6.5 ± 1.7 mm, and the mean horizontal augmentation was 5.5 ± 1.9 mm. Implant survival rate after a mean follow-up of 12 ± 6 months after reentry was 100%.ConclusionWithin the limits of the retrospective character of this study, this study shows for the first time that individualized CAD-CAM TM provide a sufficient and safe augmentation technique, especially for vertical and combined defects. However, the soft tissue handling for sufficient mesh covering remains one of the most critical steps using this technique.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.