Energy storage capacitance is necessary part of pulse power generator. Generally, it is difficult to match the equivalent capacitance in high voltage side and energy storage capacitance in low voltage side of the pulse transformer. Resultantly, it requires high flow capability of switch device. In this paper, three methods are presented to solve this problem based on reasons of overcurrent. The results of simulation and experiments show that the efficiency of generator was higher with the method of thyristor and inductance in reverse parallel, and this method would be the most effective resolution.
In order to meet the urgent needs of voltage measurement traceability and transfer in the construction of ultra-high voltage power grid, 1000kV series standard voltage transformer is developed as the standard instrument, and then its measurement characteristics is tested. According to the theory and construction of the series power frequency voltage ratio standard, semi-insulating transformer voltage summation is proposed to make the voltage ratio measurement of SSTV whose accuracy can reach the 0.02 level trace to the source of national power frequency ratio standard of 500kV successfully. The compatibility is better than compared to traditional voltage coefficient measuring method.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.