Abstract:The different locations of the equipment in urban distribution substations (DSSs) and the location of inlet holes and outlet holes usually result in different ventilation effect, which means the power consumed by any ventilating devices present is different. In this paper the temperature field distribution in an urban distribution substation with different locations of the equipment in the substation was calculated first, then factors influencing the temperature field distribution were investigated, and the influence of the different factors was analyzed. When the distance between the apparatus and walls exceeds 3 m, the change of the temperature in the DSS is very small. Therefore considering the floor area of the DSS, 3 m is the best value of the distance between the apparatus. With the change of the environment temperature or the velocity of the ventilation fans, the maximum temperature in the DSS or apparatus will change. Hence an energy saving ventilation strategy is proposed in the paper, and an intelligent cooling control system is developed, which can modify the velocity of the ventilation fans according to the environment temperature, and thus realize energy savings.
The paper describes an electric field measurement method based electroscope system to check the electrification state of ultra-high voltage transmission lines, which is composed of three parts: 1) Measuring terminal; 2) Central sever; 3) GPRS and Internet network. The measuring terminal was used to measure the electric field and the location of the measuring points, then the measured data was sent to the central sever by GPRS and Internet network, and requested for an electricity state confirmation.When the sever received a request from a terminal, the electric fields and locations of the measuring points were obtained first, then according to the location of the measuring points, the server searches the corresponding objective transmission lines in the database and read their parameters. According to the parameters of the measuring points and transmission lines, a calculation would be carried out to confirm the electrification state of the transmission lines. For the confirmation calculation, equations for the electric field inverse problem of the transmission lines were set up first, then global regularization and damped Gauss Newton (DGN) method were used to solve the inverse problem.A 500kV double loops transmission line was taken as an example to verify the validity of this method. The electric field and location of 11 measuring points were measured by the measuring terminal firstly, and then sent to the central sever. Electrification state was confirmed by the central sever.
In the paper the temperature filed distribution in a urban distribution substation in Chongqing was calculated firstly. According to the parameters of the distribution substation and apparatuses in it, equivalent model was setup and method to calculate the boundary conditions for the temperature field is presented. Then factors influencing the distribution of temperature field in the distribution substation were investigated, influences on the temperature field distribution from different factors are presented, based on which suggestion for the design of new urban distribution substation is presented in the end.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.