This paper demonstrates a technique on heat-assisted magnetic probe recording. The recording medium is a CoNi/Pt multilayered film, suitable for perpendicular recording. Scanning tunneling microscopy(STM) current was introduced to heat the medium locally. Pulse voltages of 2—9V, 500ns in width and 100ns in risetime were used to write marks. Marking was achieved at bias voltages higher than the threshold value 4V in the shape of circular dots with an average size of 170nm. Below the threshold, no marks were observed. A simple model qualitatively explains the experiment.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.