Reinforced Concrete (RC) beams in the building structures are usually assumed as a ‘T’-shaped beam when the effects of adjacent slab flange are considered. However, experimental studies on residual flexural behavior of ‘T’-shaped RC beams are rarely reported. The residual flexural behavior of two RC rectangular beams and one RC ‘T’-shaped beam after exposure to ISO834 standard fire were experimentally investigated in the paper. The detailed experimental results, including the measured temperatures, flexural capacity, load-deflection curves and concrete strain are presented. The effects of flange on temperature distribution and residual flexural behavior of RC beams were analyzed. The experimental results show that: (a) the assumption of plane section is applicable for RC ‘T’-shaped beam. (b) The flexural capacity of RC rectangular beam was decreased 18.5% after exposure to fire for 2 hours, but the ultimate mid-span deflection was increased 55.1%. (c) The residual flexural capacity and the ultimate mid-span deflection of RC rectangular beam after fire was respectively increased 8.4% and 9.9% due to the effect of flange.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.