In this article, the photovoltaic performance of one-axis multiple-positions sun-tracked photovoltaic panels (MP-PV) is investigated based on solar geometry and dependence of photovoltaic conversion efficiency on the incident angle (IA) of solar rays on PV panels. For such PV system, the azimuth angle (AZA) of PV panels is daily adjusted several times (M) from eastward in the morning to westward in the afternoon by rotating PV panels about inclined north-south axis (INSA) to ensure the projected incident angle (PIA) of solar rays on the plane perpendicular to INSA is always less than the specified angle θa
. Results show that, the annual electricity generation (AEG) of MP-PV increases with the increase of M, but such increase is not noticeable when M>5. For MP-PV with the tilt-angle (β) of INSA being yearly fixed (1T-MP-PV), the optimal θa
of 3P-,5P- and 7P-PV for maximizing AEG are respectively 24°, 15° and 11.5°, and their AEGs are respectively about 92%, 94% and 95% of that from similar 2-axis tracked PV panels (2A-PV). Whereas for MP-PV with the β being yearly adjusted four times at three tilts (3T-MP-PV), the optimal θa
of 3P-, 5P- and 7P-PV are respectively about 22.5°, 14.5° and 11°, and the Pa are respectively about 96%, 98% and 99% of that of similar 2A-PV systems.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.