The aim of this study is to estimate the fetal radiation dose for a pregnant patient treated for Hodgkin’s lymphoma. Due to the supradiaphragmatic extensions, two plans are used for this treatment, one for supra-clavicular and the other for cervical lymph nodes, with beam energies of 18 and 6 MV, respectively. We model the ELEKTA accelerator (Versa HD Ltd, Crawly, UK) and the pregnant patient using GATE code. The accelerator is modelled based on the vendor-supplied data and the pregnant patient is modeled with a voxelized pregnant woman phantom (Katja, 29 years old) at the 24th week of pregnancy. In each plan, we estimate the absorbed dose of each fetus organ by delivering a 2 Gy for one fraction and then multiplying the result by 15 fractions to get the total prescribed dose, then we calculate the mean fetal absorbed dose. The results indicate that the mean absorbed fetal dose was 26.18 mGy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.