We describe the first ever implementation of an emulsion multi-stage shifter in an accelerator neutrino experiment. The system was installed in the neutrino monitor building in J-PARC as a part of a test experiment T60 and stable operation was maintained for a total of 126.6 days. By applying time information to emulsion films, various results were obtained. Time resolutions of 5.3 to 14.7 s were evaluated in an operation spanning 46.9 days (time resolved numbers of 3.8-1.4×10 5 ). By using timing and spatial information, a reconstruction of coincident events that consisted of high multiplicity events and vertex events, including neutrino events was performed. Emulsion events were matched to events observed by INGRID, one of near detectors of the T2K experiment, with high reliability (98.5%) and hybrid analysis was established via use of the multi-stage shifter. The results demonstrate that the multi-stage shifter is feasible for use in neutrino experiments.
Directional atherectomy (DA) was developed as a new therapeutic modality for coronary artery disease. For the past 3 years, we have applied DA intervention to vascular access failure with either poor blood flow rate or high venous pressure. DA intervention was performed on 27 lesions of 16 hemodialyzed patients. A reduction of stenosis to less than 20% of that before treatment was judged a technical success, and the rate of technical success was 84%. All patients showed adequate blood flow rates after DA intervention, indicating initial success. Although restenotic events occurred frequently, repeated DA interventions could be performed successfully. The patency rate at 1 month after DA intervention was 100%, at 3 months 93%, at 6 months 92% and at 12 months 75%. The short-term patency rate of DA was more satisfactory than the results of percutaneous transluminal angioplasty as reported by several investigators. Regarding the site of stenosis, restenotic events were relatively fewer in the lesions occurring at the native vein compared to those at graft-venous anastomotic sites. Eccentric-type stenosis was also associated with fewer restenotic events than circumferential-type stenosis. These results suggest that eccentric-type stenosis at the native vein is the most suitable lesion for the application of DA intervention in terms of long-term patency. As no severe complications occurred after DA intervention, this would appear to be a useful therapeutic modality for the correction of vascular access failure.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.