Global mineralogical mapping of Mars by the Observatoire pour la Mineralogie, l'Eau, les Glaces et l'Activité (OMEGA) instrument on the European Space Agency's Mars Express spacecraft provides new information on Mars' geological and climatic history. Phyllosilicates formed by aqueous alteration very early in the planet's history (the “phyllocian” era) are found in the oldest terrains; sulfates were formed in a second era (the “theiikian” era) in an acidic environment. Beginning about 3.5 billion years ago, the last era (the “siderikian”) is dominated by the formation of anhydrous ferric oxides in a slow superficial weathering, without liquid water playing a major role across the planet.
Abstract. The Curiosity rover discovered fine--grained sedimentary rocks, inferred to represent an ancient lake, preserve evidence of an environment that would have been suited to support a Martian biosphere founded on chemolithoautotrophy. This aqueous environment was characterized by neutral pH, low salinity, and variable redox states of both iron and sulfur species. C, H, O, S, N, and P were measured directly as key biogenic elements, and by inference N and P are assumed to have been available. The environment likely had a minimum duration of hundreds to tens of thousands of years. These results highlight the biological viability of fluvial--lacustrine environments in the post--Noachian history of Mars.
X-ray diffraction analysis of the Rocknest scoop sample is described in (23); similar analyses were performed for John Klein and Cumberland. John Klein and Cumberland were the first two drill samples collected by Curiosity. All scooped or drilled samples pass through the Collection and Handling for In situ Martian Rock Analysis (CHIMRA) sample collection and processing system (10). All powders for X-ray diffraction are processed through a 150-m sieve before delivering a portion to the CheMin inlet funnel.The sieved drill powders were placed into sample cells with 6 μm thick Mylar® windows. Mylar® contributes a minor, broad scattering signature in diffraction patterns that is generally "swamped" by diffraction from the loaded sample. In addition, an aluminized light shield also contributes "peaks" to the observed diffraction patterns. Only ~10 mm 3 of material is required to fill the active volume of the sample cell, which is a disc-shaped volume 8 mm in diameter and 175 m thick. A collimated ∼70 μm diameter X-ray beam illuminates the center of the sample cell. A piezoelectric vibration system on each cell pair shakes the material during analysis, causing grains in the cell to pass through the X-ray beam in random orientations.CheMin measures XRD and XRF data simultaneously using Co radiation in transmission geometry (11). The instrument operates in single-photon counting mode so that between each readout the majority of CCD pixels are struck by either a single X-ray photon or by no photons. In this way, the system can determine both the energy of the photons striking the CCD (XRF) and the two-dimensional (2-D) position of each photon (XRD). The energy and positional information of detected photons in each frame are summed over repeated 10-sec measurements into a "minor frame" of 30 min of data (180 frames). The 2-D distribution of Co K X-ray intensity represents the XRD pattern of the sample. Circumferential integration of these rings, corrected for arc length, produces a conventional 1-D XRD pattern. For conversion of the 2-D CCD pattern to a 1-D pattern we have used FilmScan © software from Materials Data, Inc.CheMin generally operates for only a few hours each night, when the CCD can be cooled to its lowest temperature, collecting as many minor frames as possible for the available analysis time, usually five to seven per night. XRD data were acquired over multiple nights for the John Klein and Cumberland drill samples to provide acceptable counting statistics. Total data collection times were 33.9 hr for John Klein and 20.2 hr for Cumberland. The data for individual minor frames and for each night's analysis were examined separately, and there was no evidence of any changes in instrumental parameters as a function of time over the duration of these analyses. Before sample delivery and analysis, the empty cell was analyzed to confirm that it was indeed empty before receiving the sample. The flight instrument was calibrated on the ground before flight using a quartz-beryl standard, and measurement of this st...
The OMEGA/Mars Express hyperspectral imager identified hydrated sulfates on light-toned layered terrains on Mars. Outcrops in Valles Marineris, Margaritifer Sinus, and Terra Meridiani show evidence for kieserite, gypsum, and polyhydrated sulfates. This identification has its basis in vibrational absorptions between 1.3 and 2.5 micrometers. These minerals constitute direct records of the past aqueous activity on Mars.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.