The aim of this paper was to develop and validate the stability indicating RP-HPLC method for the determination of Pazopanib hydrochloride in bulk and pharmaceutical dosage forms. A simple, accurate, precise, sensitive and stability indicating RP-HPLC method has been developed for the determination of Pazopanib hydrochloride in bulk drug and pharmaceutical dosage form, in which separations are done using develosil C18, 5μm, 150 × 4.6mm i.d. column at a flow rate of 1.0mL/min with an injection volume of 20μL. The beer’s law was obeyed over the concentration range of 5 - 35μg/mL. The correlation coefficient was found to be 0.996 and it showed good linearity, reproducibility, precision in this concentration range. The % recovery values were found to be within the limits, which showed that the method was accurate. The LOD and LOQ were calculated using statistical methods. The % RSD values were less than 2. The developed method was successfully applied for determination of Pazopanib hydrochloride in pharmaceutical dosage form. The results obtained are in good agreement with those obtained by using the standard method.
The aim of this paper was to develop and validate the stability indicating RP-HPLC method for the determination of Imatinib mesylate in bulk and pharmaceutical dosage forms. A simple, accurate, precise, sensitive and stability indicating RP-HPLC method has been developed for the determination of Imatinib mesylate in bulk drug and pharmaceutical dosage form, in which separations are done using develosil C18, 5μm, 150 × 4.6mm i.d. column at a flow rate of 1.0mL/min with an injection volume of 20μL. The beer’s law was obeyed over the concentration range of 5 - 35μg/mL. The correlation coefficient was found to be 0.996 and it showed good linearity, reproducibility, precision in this concentration range. The % recovery values were found to be within the limits, which showed that the method was accurate. The LOD and LOQ were calculated using statistical methods. The % RSD values were less than 2. The developed method was successfully applied for determination of Imatinib mesylate in pharmaceutical dosage form. The results obtained are in good agreement with those obtained by using the standard method.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.