Purpose To compare the topographical tear film break-up time (T-BUT) between individuals recovering from COVID-19 and control subjects using a noninvasive and noncontact technique with a Scheimpflug-Placido disc topographer.
Methods One-hundred and twenty-two eyes from 61 post-COVID-19 patients and 124 eyes from 62 control subjects were included in this prospective study. All participants underwent detailed ophthalmological examination including best-corrected visual acuity, intraocular pressure measurements, slit lamp examination, and fundoscopy as well as qualitative and quantitative evaluation of the noninvasive first tear film break-up time (NIF-BUT) and noninvasive average tear film break-up time (NIAvg-BUT) with T-BUT measured with a Sirius (CSO – Costruzione Strumenti Oftalmici S. r. l., Italy) corneal topography device.
Results The mean NIF-BUT in post-COVID-19 and control patients was 5.2 ± 3.4 vs. 6.5 ± 3.2 sec, respectively. The mean NIAvg-BUT in the corresponding groups was 7.5 ± 3.5 vs. 8.8 ± 3.0 sec, respectively. Both NIF-BUT and NIAvg-BUT were significantly lower in the post-COVID-19 group than in controls (p = 0.004 vs. 0.020). Topographical tear film break-up at any time during the test (17 sec) was observed qualitatively in 79 eyes (64.8%) in the post-COVID-19 group and 57 eyes (46%) in the control group (p = 0.003). Moreover, temporal quadrant involvement occurred significantly more frequently in the post-COVID-19 group (p = 0.028).
Conclusion Tear film stability assessment based on T-BUT showed shorter NIF-BUT and NIAvg-BUT in post-COVID-19 patients as compared to the control group. Our results suggest that post-COVID-19 patients have impaired stability of tear film, and therefore require closer monitoring regarding dry eye. In addition, tear film instability in post-COVID-19 patients can be reliably detected using a noninvasive and noncontact technique that is more comfortable for both patients and physicians.
Scheimpflug-Placido disc topographer detected significant changes in the AC parameters after LPI in all groups. However, compared with PACS and PAC, the PACG showed significant alterations in the AC parameters through 6 months.
Backgropund: Filtering bleb formation after surgical repair of penetrating globe injury is a rare occurrence. Case: A 45-year-old male who had undergone surgical repair of a corneoscleral laceration 16 months earlier presented to emergency room after blunt trauma to the left eye. His best-corrected visual acuities were 20/20 in the right eye and 20/25 in the left. An anterior segment examination found a conjunctival filtering bleb formation on scarred sclera at superotemporal location near the limbus. Anterior chamber was slightly shallow and the Seidel test was negative. Intraocular pressures were 17 mm Hg in the right eye, 7 mm Hg in the left. The fundus examination revealed no abnormal findings. The patient was treated with topical aplication of a steroid and a cycloplegic drop during three weeks. After 16 months follow-up, the visual acuity remained unchanged with the persistence of filtering bleb. IOP was 8 mm Hg in the left eye. Follow-up examinations showed no complications related to trauma. Conclusion: Blunt ocular trauma can cause dehiscence in old scleral scars and subsequent filtering bleb formation. Nepal J Ophthalmol 2013; 5(9):136-137 DOI: http://dx.doi.org/10.3126/nepjoph.v5i1.7843
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.