Abstract:We introduce an efficient ring artifact correction method for a cone-beam computed tomography (CT). In the first step, we correct the defective pixels whose values are close to zero or saturated in the projection domain. In the second step, we compute the mean value at each detector element along the view angle in the sinogram to obtain the one-dimensional (1D) mean vector, and we then compute the 1D correction vector by taking inverse of the mean vector. We multiply the correction vector with the sinogram row by row over all view angles. In the third step, we apply a Gaussian filter on the difference image between the original CT image and the corrected CT image obtained in the previous step. The filtered difference image is added to the corrected CT image to compensate the possible contrast anomaly that may appear due to the contrast change in the sinogram after removing stripe artifacts. We applied the proposed method to the projection data acquired by two flat-panel detectors (FPDs) and a silicon-based photon-counting X-ray detector (PCXD). Micro-CT imaging experiments of phantoms and a small animal have shown that the proposed method can greatly reduce ring artifacts regardless of detector types. Despite the great reduction of ring artifacts, the proposed method does not compromise the original spatial resolution and contrast.
Computational three-dimensional (3D) models of a dental structure generated from 3D dental computed tomography (CT) images are now widely used in digital dentistry. To generate precise 3D models, high-resolution imaging of the dental structure with a dental CT is required. However, a small head motion of the patient during the dental CT scan could degrade the spatial resolution of CT images to the extent that digital dentistry is no longer possible. A bench-top micro-CT has been built to evaluate the head motion effects on the dental CT images. A micro-CT has been built on an optic table with a microfocus x-ray source and a flat-panel detector. A rotation stage, placed in between the x-ray source and the detector, is mounted on two-directional goniometers that can rotate the rotation stage in two orthogonal directions while the rotation stage is performing the CT scan. The goniometers can make object motions of an arbitrary waveform to simulate head tilting or head nodding. CT images of a phantom have been taken with and without introducing the motions, and the motion effects on the CT images have been evaluated. Object motions parallel to the detector plane have greater effects on the CT images than those against the detector plane. With the bench-top micro-CT, the motion effects have been visually seen at a tiny rotational motion as small as 0.3°. The bench-top micro-CT can be used to evaluate head motion effects on the dental CT images. The projection data, taken with the motion effects, would be used to develop motion artifact correction methods for a high-resolution dental-CT.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.