All 3 techniques were reliable, functional, and effective, yielding good visual outcomes and low phaco parameters and complication rates. Biaxial microincision surgery, with the smallest incisions, induced less astigmatism and reduced all intraoperative phaco parameters except total surgical time.
ABSTRACT.Purpose: This study aimed to compare ocular wavefront aberrations for pupil diameters of 4 mm and 6 mm, and contrast sensitivity, in eyes with AcrySof IQ and AcrySof Natural intraocular lenses (IOLs). Methods: Sixty eyes of 60 patients were enrolled in this prospective randomized study. After phacoemulsification the eyes received either AcrySof IQ SN60WF or AcrySof Natural SN60AT IOLs. One month after surgery, all patients underwent complete ophthalmological examination including corneal topography, wavefront analysis for pupil diameters of 4 mm and 6 mm, and contrast sensitivity measurements with the CSV 1000E instrument under photopic and mesopic conditions with and without glare. Results: There was no statistically significant difference between groups in age, sex or other preoperative ocular characteristics (p > 0.05). Patients with AcrySof IQ IOLs had higher contrast sensitivity at 6 c.p.d. under photopic conditions, at 6 c.p.d. and 18 c.p.d. under mesopic conditions, and at 6 c.p.d., 12 c.p.d. and 18 c.p.d. under mesopic conditions with glare (p < 0.05). Corneal spherical aberration was 0.273 ± 0.074 lm in the AcrySof Natural group and 0.294 ± 0.086 lm in the AcrySof IQ group (p = 0489). Ocular spherical aberration was 0.362 ± 0.141 lm and 0.069 ± 0.043 lm (p < 0.001) for 6-mm diameter pupils and 0.143 ± 0.091 lm and 0.017 ± 0.016 lm (p < 0.001) for 4-mm diameter pupils, with AcrySof Natural and AcrySof IQ IOLs, respectively. There were no significant differences in other higher-order aberrations between the groups (p > 0.05). Conclusions: Aspherical AcrySof IQ IOLs significantly reduced spherical aberration for pupil diameters of both 4 mm and 6 mm and also improved contrast sensitivity more than spherical AcrySof Natural IOLs, especially in mesopic conditions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.