Both devices have comparable airflow resistance and are easy to insert. The OPLAC requires less insertion time, has less variation on insertion time, fits better into the laryngopharynx, is less likely to cause gastric insufflations, and has a higher sealing pressure.
A 40-year-old woman without remarkable medical history received epidural anesthesia for uterine cervix conization. Six hours after the operation, cauda equina syndrome occurred. Magnetic resonance imaging of the spine revealed epidural fluid accumulation around L5, as well as L4/5 herniated intervertebral disc found incidentally. Surgical decompression was performed with H-reflex monitoring. Epidural injection could result in cystic accumulation complicated with cauda equina syndrome.
Patient with airway stent undergoing surgery with airway involved should be performed under the support of a backup physician and equipment that are capable of handling potentially life-threatening complications of airway stent. If not, in the emergent situation of tracheal obstruction due to tracheal/bronchial stent, protruding through the stent with a suitable, small-sized endotracheal tube with Eschmann tracheal tube introducer may be an alternative skill for saving life weighted with possible complications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.