Corneal deformation parameters DA and 1st A-time were repeatable and reproducible. A thinner cornea was associated with a higher corneal deformation. Measurement of DA serves as an indicator of corneal biomechanical properties.
Myopia is very prevalent worldwide, especially among Asian populations. Orthokeratology is a proven intervention to reduce myopia progression. The current study investigated association between baseline corneal biomechanics and orthokeratology responses, and changes of corneal biomechanics from long-term orthokeratology. We fitted 59 adult subjects having myopia between −4.00D to −5.00D with overnight orthokeratology. Corneal biomechanics was measured through dynamic bidirectional corneal applanation (in terms of corneal hysteresis, CH and corneal resistance factor, CRF) and corneal indentation (in terms of corneal stiffness, S and tangent modulus, E). Subjects with poor orthokeratology responses had lower E (mean 0.474 MPa) than subjects with good orthokeratology responses (mean 0.536 MPa). Successful orthokeratology for 6 months resulted in reducing CH (reduced by 5.8%) and CRF (reduced by 8.7%). Corneal stiffness was stable, but E showed an increasing trend. Among subjects with successful orthokeratology, a higher baseline S resulted in greater myopia reduction (Pearson correlation coefficient, r = 0.381, p = 0.02).
High myopes had lower normalised corneal tangent moduli than low myopes, which indicated that their corneas were less stiff. This is the first in vivo study comparing elastic moduli of the cornea in different refractive groups. Further studies are warranted to understand whether a less stiff cornea is a cause for or an outcome from myopia development.
The corneal indentation device has good intrasession and intersession repeatability. It has good potential to measure corneal biomechanics clinically, even at different corneal regions.
Short-term orthokeratology had no significant effect on corneal tangent modulus. Changes in CH and CRF could be related to their intrinsic measurement variability. Corneal tangent modulus provided another measure of corneal biomechanics. Long-term study is required to investigate predictive role of corneal biomechanics in orthokeratology.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.