An direct competitive immunofluorescence method was developed in plate to detect chlortetracycline residues in environment using the Lumichrome as fluorescent probe. Different reaction conditions such as pH , the concentration of antigen and antibody and incubation times were assayed. Under optimized conditions, chlortetracycline can be determined in the concentration range of 1×10-8--2×10-4 mol/L, and the linear equation was y=11.363x+93.026, R2=0.99. The detection limit of this method IC90 was 3.74×10-7mol/L. The recoveries of chlortetracycline at various spiking levels in the sludge samples ranged from 95.43% to 104.26%, with relative standard deviations of 3% to 6%. These data demonstrate that the excellent performance of the proposed method in the detection of chlortetracycline in water samples.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.