The fatigue crack propagation test was carried out in order to clarify the effect of humidity on the characteristics of fatigue crack propagation in spherical graphite cast iron. Spherical graphite cast iron (FCD450) was used as a specimen. Then, two kinds of heat treatments were conducted to the material. One was an austemper treatment (ADI), the other was a quenching and tempering treatment (QT). Moreover, as cast material was added, and with these three materials fatigue crack propagation test was carried out. The experiment conformed to ASTM. Stress ratio R was 0.1, and specimen used was 1CT type, 12.5mm thick. The test was carried out at room temperature and under three or four kinds of humidity, 0, 20, 40, 60, 80%. The relationship between the characteristics of fatigue crack propagation and the crack closure which produced on fracture surface, was investigated. The obtained results were as follows.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.