It was found that in cutting deep holes, with an increase in the temperature from 20 to 80°C, the content of harmful components: 9-and 2-methylanthracene, 3-methylphenanthrene, etc., in oil-based MR-3K coolant (CL) decreases by 15-25%, i.e., they enter the air of the working zone. The
The molecular composition of the oil-based lubricating-cooling liquid SP-4 has been studied by chromato-mass-spectrometry. The regular isoprenoids 2,6,10,14-tetramethyl pentadecane and 2,6,10,14-tetramethyl hexadecane have been detected in the liquid. It is suggested that in due course isoprenoids of the p-like structure will be detected in the high-boiling fractions of paraffinic crude oils.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.