A simple, sensitive and reliable reversed phase Rapid Resolution Liquid Chromatography (RRLC) method was developed and validated for six biologically active compounds (salidroside, tyrosol, rosarin, rosavin, rosin and rosiridin) in Rhodiola rosea L. roots and powder extracts. The method uses a Phenomenex C18 (2)-HST column at 40 o C with a neutral gradient system mobile phase (H 2 O and acetonitrile), a flow rate of 1.0 mL/min, and UV detection wavelengths set at 205 and 254 nm, simultaneously. Baseline separation of the six active compounds was achieved within 8 minutes. The average percentages of rosavins (rosarin, rosavin, and rosin) in authentic R. rosea roots and root powder extracts were quantitatively determined and a characteristic R. rosea roots RRLC profile was established. The RRLC method is accurate and sensitive; in addition, it effectively increases the sample analysis throughput compared with conventional HPLC.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.