The KVC facilitated intubation by novice personnel without incidence of esophageal intubation. However, intubation times, success rates, and GSID scores were similar to the values obtained with the MAC. These findings suggest that the KVC, but not the KVNC, could be used as an alternative device for intubation by novice personnel.
These results support our hypothesis and suggest that changing gas composition may alter delivered tidal volume of anesthesia machines with built-in ventilators that are feedback-controlled by uncorrected flowmeters due to changes in gas mixture density.
Background
Expiratory flow-initiated pressure-controlled inverse ratio ventilation (EF-initiated PC-IRV) reduces physiological dead space. We hypothesised that EF-initiated PC-IRV would be lung protective compared with volume-controlled ventilation (VCV).
Methods
Twenty-eight men undergoing robot-assisted laparoscopic radical prostatectomy were enrolled in this randomised controlled trial. The EF-initiated PC-IRV group (n = 14) used pressure-controlled ventilation with the volume guaranteed mode. The inspiratory to expiratory (I:E) ratio was individually adjusted by observing the expiratory flow-time wave. The VCV group (n = 14) used the volume control mode with a 1:2 I:E ratio. The Mann–Whitney U test was used to compare differences in the serum cytokine levels.
Results
There were no significant differences in serum IL-6 between the EF-initiated PC-IRV (median 34 pg ml-1 (IQR 20.5 to 63.5)) and VCV (31 pg ml-1 (24.5 to 59)) groups (P = 0.84). The physiological dead space rate (physiological dead space/expired tidal volume) was significantly reduced in the EF-initiated PC-IRV group as compared with that in the VCV group (0.31 ± 0.06 vs 0.4 ± 0.07; P<0.001). The physiological dead space rate was negatively correlated with the forced vital capacity (% predicted) in the VCV group (r = -0.85, P<0.001), but not in the EF-initiated PC-IRV group (r = 0.15, P = 0.62). Two patients in the VCV group had permissive hypercapnia with low forced vital capacity (% predicted).
Conclusions
There were no differences in the lung-protective properties between the two ventilatory strategies. However, EF-initiated PC-IRV reduced physiological dead space rate; thus, it may be useful for reducing the ventilatory volume that is necessary to maintain normocapnia in patients with low forced vital capacity (% predicted) during robot-assisted laparoscopic radical prostatectomy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.