This paper reports the experimental and theoretical study of the surge occurred in prototyping an ultra micro centrifugal compressor. As the first step, the 10 times size model of an ultra micro centrifugal compressor having the 40 mm outer diameter was designed and manufactured. The detailed experimental investigations for the transient behavior of surge with several different values of B parameter were carried out. The experimental results during the surge were compared with those obtained by the non-linear lumped parameter theory in order to validate the effectiveness of the theoretical surge model for the micro centrifugal compressor. As a result, the quite different behavior of the surge appeared for the different values of B both in the experiment and in the analysis.K eywords: micro centrifugal compressor, surge, lumped parameter model. CLC number: TK474.8 + 2 Document code: A
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.