A nuclear power plant operation requires reliability safety systems. Therefore, an accidental scenario such as the LOCA becomes a specific attention. This relates to a countercurrent flow phenomenon which permits the occurrence of a flooding regime. This study aims to investigate the effets of I/D ratios of the riser on the onset of flooding and time-series voltage fluctuations of differential pressure signals of the flooding regime on a complex geometry representing a PWR hot leg. The test section contains a combination of a horizontal, an elbow and an inclined pipes. Three I/D ratios containing 1.9 (R1), 3.9 (R2) and 8.3 (R3) were assesed. The tabulated data are expressed in the term of a flooding curve. Meanwhile, the statistical features of the time-series voltage fluctuations of the signals are presented on both PDF and PSD graphs. The results obtained show that the assesed I/D ratios do not conduct significance effects on the onset of flooding. On the other hand, there are trends which can be obtained from the time-series signals with the increase of the I/D ratio. Those trends can also be observed in the such statistical features; the PDF and PSD graphs, respectively.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.