Stress corrosion cracking (SCC) behaviours of Z3CN20-09M stainless steel in high temperature water containing Cl− were studied. The results indicated that SCC sensitivity was inconsistent with test temperature. The minimum and maximum of SCC sensitivity occurred at 320 and 290°C respectively, and SCC sensitivity at 250°C fell between them. SCC crack initiated preferentially at bottom of corrosion pit or along phase boundary between austenite and ferrite, and its propagation depended on relative orientation to the phase boundary. SCC crack parallel to the phase boundary propagated along the phase boundary, while that perpendicular to the phase boundary was hindered to propagate.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.