High oscillatory shear index might be the major hemodynamic characteristic of the string phenomenon in internal thoracic artery graft. The inverse graft flow and the difference in graft flow caused by clamping the stenosis can be used to evaluate the probability of observing the string phenomenon.
A novel technique that simultaneously measures three-dimensional model geometry, as well as surface pressure distribution, with single camera is demonstrated in this study. The technique takes the advantage of light-field photography which can capture three-dimensional information with single light-field camera, and combines it with the intensity-based pressure-sensitive paint method. The proposed single camera light-field three-dimensional pressure measurement technique (LF-3DPSP) utilises a similar hardware setup to the traditional two-dimensional pressure measurement technique, with exception that the wind-on, wind-off and model geometry images are captured via an in-house-constructed light-field camera. The proposed LF-3DPSP technique was validated with a Mach 5 flared cone model test. Results show that the technique is capable of measuring three-dimensional geometry with high accuracy for relatively large curvature models, and the pressure results compare well with the Schlieren tests, analytical calculations, and numerical simulations.
Our previous study indicated that 8 patients from a family with a history of congenital heart disease had simple atrial septal defect (ASD) and carried the same mutation at codon 310 in the GATA4 gene. In the present study, to identify the functional defects caused by this mutation in an in vivo model, the transgene DNA constructs were microinjected into mice to generate a transgenic mouse model. The mice were genotyped using PCR and DNA sequencing. Protein expression was measured by western blot analysis. qPCR was used to determine the copy number of the transgenes. The heart tissue was fixed and sectioned by conventional procedures. The Vevo 2000 system was used to perform echocardiography on the mice. The expression of GATA4 target genes was measured using the real-time PCR system. The incidence of ASD in the heterozygous transgenic mice was found to be greater than that in the wild-type control mice (P<0.05). In addition, the expression of α-myosin heavy chain (α-MHC) in the heart tissues from the homozygous mice was lower than that in the heart tissues from their wild-type littermates (P<0.05). In conclusion, these results suggest that the introduction of GATA4 M310V negatively affects the normal expression of α-MHC. In accordance with previous findings on GATA4 mutation screening and in vitro experiments, this study confirms that GATA4 M310V mutation may lead to the development of the congenital heart defect, ASD.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.