This article reports results of the first investigations on indoor radon, thoron and their decay products concentration in 25 primary schools of Banja Luka, capital city of Republic Srpska. The measurements have been carried out in the period from May 2011 to April 2012 using 3 types of commercially available nuclear track detectors, named: long-term radon monitor (GAMMA 1)- for radon concentration measurements (C(Rn)); radon-thoron discriminative monitor (RADUET) for thoron concentration measurements (C(Tn)); while equilibrium equivalent radon concentration (EERC) and equilibrium equivalent thoron concentrations (EETC) measured by Direct Radon Progeny Sensors/Direct Thoron Progeny Sensors (DRPS/DTPS) were exposed in the period November 2011 to April 2012. In each school the detectors were deployed at 10 cm distance from the wall. The obtained geometric mean concentrations were C(Rn) = 99 Bq m(-3) and C(Tn) = 51 Bq m(-3) for radon and thoron gases respectively. Those for equilibrium equivalent radon concentration (EERC) and equilibrium equivalent thoron concentrations (EETC) were 11.2 Bq m(-3) and 0.4 Bq m(-3), respectively. The correlation analyses showed weak relation only between C(Rn) and C(Tn) as well as between C(Tn) and EETC. The influence of the school geographical locations and factors linked to buildings characteristic in relation to measured concentrations were tested. The geographical location and floor level significantly influence C(Rn) while C(Tn) depend only from building materials (ANOVA, p ≤ 0.05). The obtained geometric mean values of the equilibrium factors were 0.123 for radon and 0.008 for thoron.
The main goal of this paper is to create an adaptive model based on multilayer perceptron (MLP) for prediction of average downlink (DL) data throughput per user and average DL data throughput per cell within an LTE network technology and in a geo-space that includes a segment of the Motorway 9th January with the access roads. The accuracy of model prediction is estimated based on relative error (RE). With multiple trainings and testing of 30 different variants of the MLP model, with different metaparameters the final model was chosen whose average accuracy for the Cell Downlink Average Throughput variable is 89.6% (RE = 0.104), while for the Average User Downlink Throughput variable the average accuracy is 88% (RE = 0.120). If the coefficient of determination is observed, the results showed that the accuracy of the best selected prediction model for the first variable is 1.4% higher than the accuracy of the prediction of the selected model for the second dependent variable. In addition, the results showed that the performance of the MLP model expressed over R2 was significantly better compared to the reference multiple linear regression (MLR) model used.
We present a method for the estimation of annual radon concentration based on short-term (three months) measurements. The study involves results from two independent sets of indoor radon concentration measurements performed in 16 cities of the Republic of Macedonia. The first data set contains winter and annual radon concentration obtained during the National survey in 2010 and the second, contains only the radon concentration measured during the winter of 2013. Both data sets pertain to radon concentration from the same cities and have been measured applying the same methodology in ground floor dwellings. The results appeared to be consistent and the dispersion of radon concentration was low. Linear regression analysis of the radon concentration measured in winter of 2010 and of the 2010 annual radon concentration revealed a high coefficient of determination R2 = 0.92, with a relative uncertainty of 3%. Furthermore, this model was used to estimate the annual radon concentration solely from winter-term measurements performed in 2013. The geometrical mean of the estimated annual radon concentration of the 2013: radon concentration (A-2013) =98 Bqm-3 was almost equal to the geometrical mean of the annual radon concentration from the 2010, radon concentration (A-2010) = 99 Bqm-3. Analysis of the influence of building characteristics, such as presence/absence of a basement in the building, or the dominant building material on the estimated annual radon concentration is also reported. Our results show that a low number of relatively short-term radon measurements may produce a reasonable insight into a gross average obtained in a larger survey.
This article deals with the variation of radon (Rn), thoron (Tn) and their progeny concentrations expressed in terms of equilibrium equivalent concentrations (EERC and EETC), in 40 houses, in four villages of Sokobanja municipality, Southern Serbia. Two types of passive detectors were used: (1) discriminative radon-thoron detector for simultaneous Rn and Tn gases measurements and (2) direct Tn and Rn progeny sensors (DRPS/DTPS) for measuring Rn and Tn progeny concentrations. Detectors were exposed simultaneously for a single period of 12 months. Variations of Tn and EETC appear higher than those of Rn and EERC. Analysis of the spatial variation of the measured concentrations is also reported. This work is part of a wider survey of Rn, Tn and their progeny concentrations in indoor environments throughout the Balkan region started in 2011 year.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.