In summary, midterm results of use of covered chimney stents for pararenal aortic pathologies show safety and feasibility with excellent patency and low incidence of endoleaks.
In this 102 patient contemporary series of eEVAR for RAAA, endografting proved to be safe with a 30-day mortality of 13%. Key components of this favorable outcome result were adequate preoperative diagnostic imaging, hypotensive hemostasis, selective transfemoral supraceliac aortic balloon occlusion, predominantly local anesthesia, detection and treatment of ACS, and attention to logistics. Widespread adoption of these treatment components is recommended.
Background-Mycotic aortic aneurysm (MAA) is a rare and life-threatening disease. The aim of this European multicenter collaboration was to study the durability of endovascular aortic repair (EVAR) of MAA, by assessing late infectionrelated complications and long-term survival. Methods and Results-All EVAR treated MAAs, between 1999 and 2013 at 16 European centers, were retrospectively reviewed. One hundred twenty-three patients with 130 MAAs were identified. Mean age was 69 years (range 39-86), 87 (71%) were men, 58 (47%) had immunodeficiency, and 47 (38%) presented with rupture. Anatomic locations were ascending/arch (n=4), descending (n=34), paravisceral (n=15), infrarenal aorta (n=63), and multiple (n=7). Treatments were thoracic EVAR (n=43), fenestrated/branched EVAR (n=9), and infrarenal EVAR (n=71). Antibiotic was administered for mean 30 weeks. Mean follow-up was 35 months (range 1 week to 149 months). Six patients (5%) were converted to open repair during follow-up. Survival was 91% (95% confidence interval, 86% to 96%), 75% (67% to 83%), 55% (44% to 66%), and 41% (28% to 54%) after 1, 12, 60, and 120 months, respectively. Infection-related death occurred in 23 patients (19%), 9 after discontinuation of antibiotic treatment. A Cox regression analysis demonstrated non-Salmonellapositive culture as predictors for late infection-related death.
Conclusions-Endovascular
PURPOSE: To evaluate the performance of periscope and/or chimney grafts (CPGs) in the endovascular treatment of pararenal or thoracoabdominal aneurysms using off-the-shelf devices. METH-ODS: Between February 2002 and August 2012, 77 consecutive patients (62 men; mean age 73±9 years) suffering from pararenal aortic (n=55), thoracoabdominal (n=16), or arch to visceral artery aneurysms (n=6) were treated with aortic stent-graft implantation requiring chimney and/or periscope grafts to maintain side branch perfusion. CPGs were planned in advance and were not used as bailout. A standardized follow-up protocol including computed tomographic angiography, laboratory testing, and clinical examination was performed at 6 weeks; 3, 6, and 12 months; and annually thereafter. RESULTS: Technical success was achieved in 76 (99%) patients; 1 branch stent-graft became dislocated from a renal artery, which could not be re-accessed. Overall, 169 target vessels (121 renal arteries, 30 superior mesenteric arteries, 17 celiac trunks, and 1 inferior mesenteric artery) were addressed with the chimney graft configuration in 111 and the periscope graft configuration in 58. In total, 228 devices were used for the CPGs: 213 Viabahn stent-grafts and 15 bare metal stents. Over a mean 25±16 months (range 1-121), 9 patients died of unrelated causes. Nearly all (95%) of the patients demonstrated a decreased or stable aneurysm size on imaging; there was a mean 13% shrinkage in aneurysm diameter. Twenty patients had primary type I/III endoleaks at discharge; in follow-up, only 3 of these were still present (no secondary or recurrent endoleaks were noted). Additional endovascular maneuvers were required for CPG-related complications in 13 patients from intervention throughout follow-up. Overall, 4 CPGs occluded (98% target vessel patency); no stent-graft migration was observed. Renal function remained stable in all patients. CONCLUSION: In this series, the use of CPGs has proven to be a feasible, safe, and effective way to treat thoracoabdominal and pararenal aneurysms with maintenance of blood flow to the renovisceral arteries. Nearly all of the aneurysms showed no increase in diameter over a >2-year mean follow-up, which supports the midterm adequacy of the CPG technique as a method to effectively revascularize branch vessels with few endoleaks or branch occlusions.
The diagnostic accuracy of FDG-PET/CT in the detection of aortic graft infection is high. A newly introduced five point visual grading score and early imaging prior to antimicrobial treatment may further improve the diagnostic accuracy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.