A lower chemotherapeutic load and a small number of allogeneic BMTs did not affect total positive treatment results in adult patients with ALL, by complying with the principle achieving the continuity of cytostatic effects and by preserving the total cytostatic loading dose. The results of the Russian investigation casts some doubt on the necessity of using very intensive consolidation cycles and performing a large number of allogeneic BMTs in adult patients with ALL.
Introduction The presence of the CD157 GPI-protein on both monocytes and granulocytes only gives opportunity to use it as a target for paroxysmal nocturnal hemoglobinuria (PNH) phenotype cells detection instead of CD24 and CD14, thus improving the technique of PNH-cells evaluation. In present study we used standard technique (International Clinical Cytometry Society (ICCS) guideline proposal) together with 5 color combination of mAbs for detection of PNH-clone on the monocytes and granulocytes simultaneously in one test-tube. Objectives: improvement of PNH cells detection technique. Materials and methods: Blood samples were collected from 37 patients (pts) with bone marrow failure syndrome (aplastic anemia – 34 pts., PNH - 2 pts., myelodysplastic syndrome – 1 pt.; 23 female and 14 men; median age 24 (15 to 66). PNH clone was detected by flow cytometry in all 37 pts. Three healthy donors were in control group. The comparison of the standard 4-color technique of PNH clone size detection on monocytes (FLAER, CD14, CD64, CD45 reagents) and on granulocytes (FLAER, CD24, CD15, CD45 reagents) with the 5-color technique using CD157 GPI-protein antibodies for the both cells populations in one test-tube (FLAER, CD157, CD15, CD64, CD45) were performed. Results: Both methods showed the same high sensitivity for determining of PNH clone. The correlation coefficient was 0,9994 for granulocytes and 0,9924 for monocytes (Figure 1). Figure 1 Figure 1. In group of patients with minor PNH-clone (range from 0,01% to 0,99%) the clone size was twice times bigger on monocytes compared to granulocytes using the standard method, whereas with antibodies against CD157 this difference disappeared. In patients with PNH-clone between 1% and 10% the clone was nearly three times less on granulocytes than monocytes using both methods; in the group with clone more than 10% there was no differences between cells populations. Table 1. Average value of PNH clone on leukocytes in groups of patients both techniques PNH clone Gr, % (mean) Mon, % (mean) CD24-/FLAER- CD157-/FLAER- CD14-/FLAER- CD157-/FLAER- 0%-0,99% 0,178 0,349 0,323 0,378 1%-9,99% 3,98 3,76 9,54 9,98 >10% 71,52 71,52 71,85 71,34 Conclusion: The results of the PNH clone detection obtained with CD157 mAbs are comparable with the standard technique proposed by ISSC. However, the use of CD157 antibodies has important advantage: the PNH clone size detection in one test-tube with 5-color combination reduces time and expenses. Additionally, using of 5-color CD157 antibodies kit would be preferable for the monitoring and detection of minor PNH clone. Disclosures No relevant conflicts of interest to declare.
The ALL-2009 protocol allows both the federal and regional centers to obtain the long-term results comparable with those of current foreign studies: OS (54.2%), RFS (56.5%); and relapse risk (35.4%). Multivariate analysis has identified age (over 30 years), initial leukocytosis (30·109/l and more) and t(4;11) among the main clinical prognostic factors. Gene mutation detection evaluated in a small number of patients (8/36) is not a poor prognostic sign. There is a need for further investigations with centralized evaluation of the mutation status of leukemic cells and the clearance of minimal residual disease.
Introduction. Cryosupernatant is blood component. Cryosupernatant is the supernatant plasma removed during the preparation of cryoprecipitate. Aim. To provide information on the composition and methods of production, storage, transportation and clinical use of Cryosupernatant. General fi ndings. In comparison with fresh frozen plasma (FFP) and cryoprecipitate, Cryosupernatant plasma is depleted in factor VIII, fi brinogen factor von Willebrand (VWF). Cryosupernatant is defi cient in high molecular weight multimers of VWF, but contains VWF metalloproteinase. The concentrations of factor V, antithrombin III, albumin and immunoglobulins are the same as in FFP and cryoprecipitate. The indications for Cryosupernatant transfusions are massive blood loss in patients with factor VIII inhibitor, plasma exchange in patients with thrombotic thrombocytopenic purpura. For children the doses of Cryosupernatant should be 10-15 mL/kg.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.