The paper considers the possibility of monitoring reliability of infrared spectroradiometer operation when detecting the presence of a toxic chemical in a dusty atmosphere. We present a method for estimating cumulative concentration of aerosol particles based on evaluating variations in contrast of a test object against the background in the visible wavelength range during gas and aerosol cloud propagation. In order to determine the critical contrast value that corresponds to the aerosol concentration designating further inability of the spectroradiometer to detect the toxic chemical in the air, we propose to numerically solve the problem of radiation transfer in a medium with known parameters. We report the results of solving this problem for an interfering aerosol consisting of water droplets with a diameter of 5--20 µm. We show that for a signal-to-noise ratio of 100 it is possible to detect a toxic chemical at aerosol concentrations of up to 5 g/m2. Implementing the method proposed involves using a video camera to monitor the test object and a computer to process the images recorded.
Введение. Выброс облака токсичного химиката при аварии на предприятии хи-мической промышленности представляет собой существенную угрозу для жиз-ни и здоровья людей [1][2][3]. В связи с этим своевременное установление факта аварии и образования облака, содержащего токсичный химикат, является осно-вой обеспечения защиты как работников предприятия, так и населения, прожи-вающего вблизи аварийного объекта [4][5][6].Одним из наиболее эффективных технических средств, позволяющим определить не только факт аварии, но и оценить масштабы выброса, является спектрорадиометр, регистрирующий инфракрасные спектры газообразных ве-ществ [6][7][8][9]. Однако наличие в облаке выброса, кроме газообразных веществ, также и аэрозольных частиц может повлиять на корректность работы такого прибора.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.