Objective. To assess the effectiveness of the application of adhesion barrier gel Antiadgezin to prevent the development of cicatricial adhesive process and its complications in the spinal canal after decompression surgery for degenerative disease in the lumbar spine.
Multiple-day distraction regenerate contains a number of foci or zones merging into one another with different structural organization of the fibrocellular basis that reflects successive stages of reparative regeneration. At the moment of the last traction, the central part of the regenerate represents a zone of fibrogenesis (growth zone), which is common for the proximal and distal parts of the distraction regenerate. The other zones are paired and symmetrical: zones of angiogenesis, fibrous osteogenesis (primary), and osteogenesis (secondary). The latter include subzones of resorption, secondary osteogenesis, and functional remodeling.
Background
The paper covers modern approaches to the evaluation of neoplastic processes with diffusion-weighted imaging (DWI) and proposes a physical model for monitoring the primary quantitative parameters of DWI and quality assurance. Models of hindered and restricted diffusion are studied.
Material and method
To simulate hindered diffusion, we used aqueous solutions of polyvinylpyrrolidone with concentrations of 0 to 70%. We created siloxane-based water-in-oil emulsions that simulate restricted diffusion in the intracellular space. To obtain a high signal on DWI in the broadest range of b values, we used silicon oil with high T2: cyclomethicone and caprylyl methicone. For quantitative assessment of our phantom, we performed DWI on 1.5T magnetic resonance scanner with various fat suppression techniques. We assessed water-in-oil emulsion as an extracorporeal source signal by simultaneously scanning a patient in whole-body DWI sequence.
Results
We developed phantom with control substances for apparent diffusion coefficient (ADC) measurements ranging from normal tissue to benign and malignant lesions: from 2.29 to 0.28 mm2/s. The ADC values of polymer solutions are well relevant to the mono-exponential equation with the mean relative difference of 0.91%.
Conclusion
The phantom can be used to assess the accuracy of the ADC measurements, as well as the effectiveness of fat suppression. The control substances (emulsions) can be used as a body marker for quality assurance in whole-body DWI with a wide range of b values.
At present the oncologists have great potentialities in diagnostic techniques that enable to determine not only the structural but functional characteristics of the tumor as well. The use of modern technologies of medical visualization for diagnosis, determination of the disease stage and effectiveness of neoadjuvant chemotherapy in patients with bone sarcomas of high degree (G3-G4) malignancy is presented.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.