Recent studies on the fatigue assessment of high strength steel weld based on the fracture mechanics have frequently raised the problems related to the conservatism in the fatigue crack growth rate specified in the relevant design code. The purpose of this study is to evaluate the effect of the fatigue crack growth parameter on the fatigue life for the low carbon steel weld. In order to do it, the fatigue tests with the constant stress ratio were performed to evaluate the fatigue crack growth rate in the butt weld of SM490. And the fatigue crack growth parameters of the weld were evaluated in accordance with ASTM E647. From the comparative fatigue assessment results, it was found that the fatigue crack growth rate specified in the relevant design code was too conservative to estimate the residual fatigue life of welded structure. So, in order to get the more reliable results, it was recommended that the fatigue life estimation based on the fracture mechanics be performed with the fatigue crack growth parameter specified by test.
Trauma is frequently implicated in the development of sarcomas, including rhabdomyosarcoma. Rare soft tissue sarcomas have been reported to arise in scar tissue following surgical procedures or thermal or acid burns, at fracture sites, and in the vicinity of plastic or metal implants, usually after a latent period of several years. The authors encountered a case of a rhabdomyosarcoma arising from the forearm crushed by a conveyor belt 11 years ago. Several possible etiological factors for sarcoma development were identified in this patient, including tissue damage and inflammation, as well as the presence of metal implants and the limb's exposure to radiation during multiple imaging tests. After severe soft tissue damage, the occurrence of a sarcoma should be considered and more attention should be paid to the causative factors for sarcoma.
The purpose of this study is to evaluate the redistribution of transverse residual stress in the multi-pass FCA butt weld of YP47 in the hatch coaming top plate of ultra large size containership under the tensile cyclic load. In order to do it, the configuration of modified H type specimen including restraint length was first designed to simulate the restraint condition of the butt weld in hatch coaming top plate. FE analysis procedure for evaluating the transverse residual stress was verified by comparing the calculated mean and surface residual stresses with the measured results in the test specimen. After that, the effect of the cyclic load on the redistribution of transverse residual stress was evaluated by comprehensive FEA. From the results, it was found that although the maximum transverse residual stress decreased with an increase in the applied maximum load, the effect of the cyclic load on the mean residual stress is small enough to be negligible. It is because the maximum stress of the ship corresponding to the probability of 10E-8 is less than 70% of yield stress of the weld.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.