2022
DOI: 10.3390/app12146916
|View full text |Cite
|
Sign up to set email alerts
|

2D CFD Simulation of Dynamic Heat Transfer in an Open-Type Refrigerated Display Cabinet

Abstract: This study uses a simplified two-dimensional time-dependent computational fluid dynamic (CFD) model to study the influence of wall shelf configuration and outtake honeycomb inclination angle on the performance of the air curtain in an open-type semi-vertical refrigerated display cabinet. Numerical simulation results show that changing the angle, along with changing the shelf configuration, can reduce the temperature of the intake air grille and improve the warm/cold air ratio. The average temperature of the si… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

1
1
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 12 publications
1
1
0
Order By: Relevance
“…In this paper, an experimental study of energy efficiency and temperatures inside an open-type semivertical refrigerated cabinet is reported. This study con-tinues the previous research (Vengalis & Mokšin 2022) that developed and validated the Computational Fluid Dynamics (CFD) models of unmodified and modified refrigerated cabinets. This experimental study aims to compare the performance of open-type display cabinets with different honeycomb angles in terms of return air temperature and energy consumption.…”
Section: Introductionsupporting
confidence: 77%
See 1 more Smart Citation
“…In this paper, an experimental study of energy efficiency and temperatures inside an open-type semivertical refrigerated cabinet is reported. This study con-tinues the previous research (Vengalis & Mokšin 2022) that developed and validated the Computational Fluid Dynamics (CFD) models of unmodified and modified refrigerated cabinets. This experimental study aims to compare the performance of open-type display cabinets with different honeycomb angles in terms of return air temperature and energy consumption.…”
Section: Introductionsupporting
confidence: 77%
“…The infiltration ratio shows how effectively the air curtain works in the open-type refrigerated cabinet. It was calculated according to the formula presented in (Vengalis & Mokšin 2022). For an unmodified cabinet, the infiltration ratio is 38.7% and in the case of the modified design, the infiltration ratio decreases to 27.7%.…”
Section: Resultsmentioning
confidence: 99%