2018
DOI: 10.1002/jmri.26532
|View full text |Cite
|
Sign up to set email alerts
|

3D Chemical Shift‐Encoded MRI for Volume and Composition Quantification of Abdominal Adipose Tissue During an Overfeeding Protocol in Healthy Volunteers

Abstract: Background Overweight and obesity are major worldwide health concerns characterized by an abnormal accumulation of fat in adipose tissue (AT) and liver. Purpose To evaluate the volume and the fatty acid (FA) composition of the subcutaneous adipose tissue (SAT) and the visceral adipose tissue (VAT) and the fat content in the liver from 3D chemical‐shift‐encoded (CSE)‐MRI acquisition, before and after a 31‐day overfeeding protocol. Study Type Prospective and longitudinal study. Subjects Twenty‐one nonobese healt… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

4
31
1
1

Year Published

2018
2018
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 23 publications
(37 citation statements)
references
References 36 publications
4
31
1
1
Order By: Relevance
“…[33][34][35] MRS in Ward's triangle and femoral neck showed similar results to CSE-MRI, with good measurement agreement according to the Bland-Altman method. This result is similar to previous studies, which validated CSE-MRI with: 1) MRS to assess fat quantity and composition in the liver, spine, and bone marrow, 17,18,[20][21][22]36 and 2) more recently, gas chromatography of subcutaneous adipose tissue. 22 Spectral quality was assessed by measurement of the quality factor, methyl protons, and water peak lineshape (reflecting static field homogeneity in the selected voxel).…”
Section: Discussionsupporting
confidence: 91%
See 3 more Smart Citations
“…[33][34][35] MRS in Ward's triangle and femoral neck showed similar results to CSE-MRI, with good measurement agreement according to the Bland-Altman method. This result is similar to previous studies, which validated CSE-MRI with: 1) MRS to assess fat quantity and composition in the liver, spine, and bone marrow, 17,18,[20][21][22]36 and 2) more recently, gas chromatography of subcutaneous adipose tissue. 22 Spectral quality was assessed by measurement of the quality factor, methyl protons, and water peak lineshape (reflecting static field homogeneity in the selected voxel).…”
Section: Discussionsupporting
confidence: 91%
“…This result is similar to previous studies, which validated CSE-MRI with: 1) MRS to assess fat quantity and composition in the liver, spine, and bone marrow, 17,18,[20][21][22]36 and 2) more recently, gas chromatography of subcutaneous adipose tissue. 22 Spectral quality was assessed by measurement of the quality factor, methyl protons, and water peak lineshape (reflecting static field homogeneity in the selected voxel). In our study we used the STEAM sequence, which compared with PRESS has the advantage of being less sensitive to homonuclear scalar coupling and short T 2 relaxation times, as explained in Hamilton et al 37 Quantification was processed by the AMARES method and calculated Cramer-Rao lower bounds showed very low values, which indicate very low variances in the case of unbiased estimators.…”
Section: Discussionsupporting
confidence: 91%
See 2 more Smart Citations
“…İnsülin duyarlılığı ise kantitatif olarak QUICKI-IS (Quantitative Insulin Sensitivity Check Index) indeksine göre hesaplanmıştır. 18 25 Bu önemlidir çünkü intraabdominal yağ maternal metabolizmayı en çok etkileyen aktif adipoz doku kısmıdır. 26 Bu yöntemler adipoz doku ile insülin rezistansı arasındaki ilişkiyi daha iyi gösterse de çalışmamızda gebelerde uygulanabilirliği , pratik oluşu, maliyet ve sonuçlarının yorumlanmasındaki tahmini güçlüklerden dolayı antropometrik subkutan yağ doku ölçümü kullanılmıştır.…”
Section: Laboratuar çAlışmalarıunclassified