99% Efficient 10 kV SiC-Based 7 kV/400 V DC Transformer for Future Data Centers

Abstract: The power supply chain of data centers from the medium voltage (MV) utility grid down to the chip level voltage consists of many series connected power conversion stages and accordingly shows a relatively low efficiency. Solid-State Transformers (SSTs) could improve the efficiency by substantially reducing the number of power conversion stages and/or directly interfacing the MV AC grid to a 400 V DC bus, from where server racks with a power consumption of several tens of kilowatts could be supplied by individu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
70
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
4
1
1

Relationship

1
5

Authors

Journals

citations
Cited by 227 publications
(70 citation statements)
references
References 36 publications
0
70
0
Order By: Relevance
“…Zero Voltage Switching (ZVS) is achieved for all semiconductors and, therefore, the SST can be operated at 48 kHz. More details about this SST can be found in [10], [51]. The MV/MF transformer, which is operated inside the DC-DC converter, is subject to all identified critical aspects with respect to dielectric losses: high-frequency, high switching speed, large common-mode (CM) voltages, and large differential-mode (DM) voltages.…”
Section: A Transformer Designmentioning
confidence: 99%
See 4 more Smart Citations
“…Zero Voltage Switching (ZVS) is achieved for all semiconductors and, therefore, the SST can be operated at 48 kHz. More details about this SST can be found in [10], [51]. The MV/MF transformer, which is operated inside the DC-DC converter, is subject to all identified critical aspects with respect to dielectric losses: high-frequency, high switching speed, large common-mode (CM) voltages, and large differential-mode (DM) voltages.…”
Section: A Transformer Designmentioning
confidence: 99%
“…The stray inductance of the transformer, together with the series capacitor located on the LV side, is used as a resonant tank [5], [23]. The DC-DC converter is operated at the resonance frequency and ZVS is achieved with the magnetizing current of the transformer [10]. This implies that the switched current is nearly load-independent and that the switching transitions feature a limited speed, which is beneficial for the dielectric losses [9], [23].…”
Section: A Transformer Designmentioning
confidence: 99%
See 3 more Smart Citations