2021
DOI: 10.1109/tia.2020.3028341
|View full text |Cite
|
Sign up to set email alerts
|

A 36-Pulse AC–DC Converter With DC-Side Tapped Interphase Bridge Rectifier for Power Quality Improvement

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
10
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 18 publications
(10 citation statements)
references
References 21 publications
0
10
0
Order By: Relevance
“…Also, the 12-pulse rectifier with the proposed PMC is superior in comparison to the 12-pulse rectifiers with the PMCs in ref. [39][40][41][42][43][44][45][46][47] both in terms of input current THD and in terms of the kVA rating. Of course, the kVA rating of 12-pulse rectifiers with PMCs in ref.…”
Section: Kilovolt Ampere Ratingmentioning
confidence: 99%
See 1 more Smart Citation
“…Also, the 12-pulse rectifier with the proposed PMC is superior in comparison to the 12-pulse rectifiers with the PMCs in ref. [39][40][41][42][43][44][45][46][47] both in terms of input current THD and in terms of the kVA rating. Of course, the kVA rating of 12-pulse rectifiers with PMCs in ref.…”
Section: Kilovolt Ampere Ratingmentioning
confidence: 99%
“…It should be noted that the proposed PMC has 2 additional diodes compared to the PMC presented in ref. [30,[39][40][41][42][43][44][45][46][47][48][49], which leads to an increase in cost, an increase in connection loss, and a decrease in efficiency. But it should be noted that the autotransformer in multi-pulse rectifiers takes the main part in cost and efficiency.…”
Section: Kilovolt Ampere Ratingmentioning
confidence: 99%
“…In [22][23][24][25][26][27][28][29][30][31] the transformers are auto-type. In [22][23][24][25] the transformers output two sets of three-phase voltages with a 30 • phase difference, and in [26][27][28] the transformers output three sets of three-phase voltages with a 20 • phase difference. In [29][30][31] the transformers output two sets of five-phase voltage with an 18 • phase difference to perform 20-pulse rectification.…”
Section: Introductionmentioning
confidence: 99%
“…Compared to the isolation type transformers, the kVA rating of the auto type transformers is reduced by about 60%. However, the rectifiers in [22][23][24][25][26][27][28][29][30][31] are all parallel-connected MPRs, and there is no precedent for using series rectifiers.…”
Section: Introductionmentioning
confidence: 99%
“…Other numbers of pulses can be used, such as a ten-pulse diode rectifier is applied in the case of five-phase generators [6]. The reduction of the harmonic distortion is due to the cancelation of the low-order harmonic currents generated by the rectifier [3], [7]. Moreover, multipulse rectifiers can operate at a near-unity power factor by increasing the number of pulses, and line current harmonic distortion is also reduced [8].…”
Section: Introductionmentioning
confidence: 99%