2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC) 2012
DOI: 10.1109/nssmic.2012.6551077
|View full text |Cite
|
Sign up to set email alerts
|

A 4-channel multiplex analyzer for real-time, parallel processing of fast scintillators

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
8
0

Year Published

2013
2013
2018
2018

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 9 publications
(8 citation statements)
references
References 5 publications
0
8
0
Order By: Relevance
“…Using a curve fitting tool a power trend was realized (4). = 1121.58 • −1.003 (4) Rearranged to make W the subject produces the model used to determine the bin width, W, required to scale the mode pulse height of the real data to the specified pulse height, M (5). Fig.…”
Section: Epj Web Of Conferences 170 07001 (2018)mentioning
confidence: 99%
See 1 more Smart Citation
“…Using a curve fitting tool a power trend was realized (4). = 1121.58 • −1.003 (4) Rearranged to make W the subject produces the model used to determine the bin width, W, required to scale the mode pulse height of the real data to the specified pulse height, M (5). Fig.…”
Section: Epj Web Of Conferences 170 07001 (2018)mentioning
confidence: 99%
“…ANY application systems adopt multiple organic scintillation detectors for fast neutron assay [1][2][3][4][5][6][7][8][9][10][11]. Detector arrays of this sort can consist of tens of detectors that rely on photo-multiplier tube (PMT) technology for scintillation light capture, voltage conversion and signal amplification.…”
Section: Introductionmentioning
confidence: 99%
“…The maturity of these two technologies, their ability to detect fast neutrons directly, perform neutron/gamma discrimination reliably and low deadtime have made them a popular choice for helium-3 alternatives [1], enhanced nuclear safeguards and security monitoring [2][3][4][5][6][7][8][9] and fast neutron imaging appli-20 cations [10,11]. Besides the choice of detector and DAQ, all these measurements analyse data from multiple detectors.…”
mentioning
confidence: 99%
“…1 functions and sensitivities [7]. In the past, this has been achieved by monitoring the detector count rates, visually inspecting the PSD scatter plots and neutron/gamma ratios derived from measurements with a Cf-252 source [4,13] (NB. PHS analysis was unavailable in this instance).…”
mentioning
confidence: 99%
See 1 more Smart Citation