1986
DOI: 10.1080/02640418608732119
|View full text |Cite
|
Sign up to set email alerts
|

A bioengineering analysis of human muscle and joint forces in the lower limbs during running

Abstract: A two-dimensional, dynamic bioengineering model of the lower limbs was developed in order to estimate muscle and joint forces present during running at 4.5 m s-1. Data were collected from four subjects using a force platform and cine film. Individual X-rays and anthropometric data from the lower limbs were utilized to produce accurate bone models of the subjects' legs. Electromyographic verification of the model was undertaken while a runner was undergoing treadmill running at 4.5 m s-1. Results indicate that … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
14
2

Year Published

1990
1990
2014
2014

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 32 publications
(17 citation statements)
references
References 17 publications
1
14
2
Order By: Relevance
“…The joint reaction forces were slightly higher but in the range of those reported by Lu, Chien and Chen [4]. Vertical joint reaction forces were smaller in magnitude than walking [17] and running [18][19][20] for all three joints investigated. The vertical joint reaction forces were highest in the low ramp positions except at the ankle where the forces were greater in the high ramp position but this difference across the ramps was not significant.…”
Section: Discussioncontrasting
confidence: 38%
See 2 more Smart Citations
“…The joint reaction forces were slightly higher but in the range of those reported by Lu, Chien and Chen [4]. Vertical joint reaction forces were smaller in magnitude than walking [17] and running [18][19][20] for all three joints investigated. The vertical joint reaction forces were highest in the low ramp positions except at the ankle where the forces were greater in the high ramp position but this difference across the ramps was not significant.…”
Section: Discussioncontrasting
confidence: 38%
“…Magnitudes were within the range of moments measured during various exercises. In contrast to running where knee moments are almost twice as large as hip moments, the hip joint moments were nearly as high as the net moments observed for the knee joint during the elliptical stride at the low ramp setting [19].…”
Section: Discussionmentioning
confidence: 67%
See 1 more Smart Citation
“…Jogging is generally considered a high-impact force with various estimates of knee forces ranging from 7 times body weight [8] up to 22 times body weight [9]. In two subjects implanted with instrumented distal femoral tumor replacement prosthesis, jogging generated peak forces of 3.6 times body weight [24].…”
Section: Discussionmentioning
confidence: 99%
“…A two-dimensional model (Harrison et al, 1986) developed to estimate muscle and joint forces during running was verified using electromyographic techniques. Results indicated muscle forces in excess of 22 times a subject's body weight.…”
Section: Biomechanics In Relation To Footwear Designmentioning
confidence: 99%