2013
DOI: 10.1016/j.talanta.2013.08.059
|View full text |Cite
|
Sign up to set email alerts
|

A carbon nanotube screen-printed electrode for label-free detection of the human cardiac troponin T

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
21
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 48 publications
(21 citation statements)
references
References 32 publications
0
21
0
Order By: Relevance
“…Increased levels of cTnT (higher than 0.3 ng mL −1 ) are highly specific to cardiac injury and are significantly associated with an increased risk of re-infarction and death, which facilities early diagnosis [93]. As shown in Table 2, Fonseca et al [93], Gomes-Filho et al [94], Silva et al [95] and Mattos et al [96] developed immunosensors based on gold nanoparticles, carboxylated CNTs, amine-functionalized CNTs and o-aminobenzoic films, respectively, for immobilizing antibodies specific to cTnT, with an LOD ranging from 0.0015 to 0.033 ng mL −1 . All immunosensors were used for serum samples with high sensitivity.…”
Section: Cardiac Biomarkersmentioning
confidence: 99%
See 1 more Smart Citation
“…Increased levels of cTnT (higher than 0.3 ng mL −1 ) are highly specific to cardiac injury and are significantly associated with an increased risk of re-infarction and death, which facilities early diagnosis [93]. As shown in Table 2, Fonseca et al [93], Gomes-Filho et al [94], Silva et al [95] and Mattos et al [96] developed immunosensors based on gold nanoparticles, carboxylated CNTs, amine-functionalized CNTs and o-aminobenzoic films, respectively, for immobilizing antibodies specific to cTnT, with an LOD ranging from 0.0015 to 0.033 ng mL −1 . All immunosensors were used for serum samples with high sensitivity.…”
Section: Cardiac Biomarkersmentioning
confidence: 99%
“…They can be used for point-of-care diagnosis of acute myocardial infarction. For example, Gomes-Filho et al [94] and Silva et al [95] compared the cTnT concentrations obtained with both immunosensors in human serum samples to the levels obtained with electrochemiluminescence immunoassays. They [94,95] obtained correlation coefficients of 0.987 and 0.990 between the two methods (p < 0.0001), respectively.…”
Section: Cardiac Biomarkersmentioning
confidence: 99%
“…To overcome this disadvantage, Silva et al (2013) had developed an amine functionalized CNTs, incorporated into the ink printing used to fabricate screen printed electrode (SPE) to detect cTnT. A better stability in measurement is enabled by incorporating NH 2 -CNT into the carbon ink.…”
Section: Carbon Nanotubes (Cnts)mentioning
confidence: 99%
“…Silva et al [39] have developed a carbon nanotube screenprinted electrode for label-free detection of the cardiac troponin T (cTnT), an important marker of acute myocardial infarction. In particular, amine-functionalized CNTs were incorporated into the printing ink used to fabricate SPEs.…”
Section: Label-free Innovative Electrochemical Immunosensorsmentioning
confidence: 99%