1966
DOI: 10.1021/j100882a009
|View full text |Cite
|
Sign up to set email alerts
|

A Comparative Study of Adsorption by Ellipsometric and Radiotracer Methods

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0

Year Published

1968
1968
2021
2021

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 20 publications
(4 citation statements)
references
References 2 publications
0
4
0
Order By: Relevance
“…Similar observations were made earlier for the adsorption of fatty acids from solutions and vapor phase which showed that there is less adsorption on mica, gold, platinum and chromium than on nickel, iron and copper. 147 Both studies revealed that surfaces become contaminated at different rates and to different levels, as a result of adsorption driven by molecule-surface interactions. White also proposed that organics can be gathered from the air by adsorption onto oxidized metal surfaces and therefore used as filling media in storage compartments to maintain surface cleanness of lower energy specimens such as glass or mica.…”
Section: Contamination Of Hydrophilic Surfaces and Their Cleaningmentioning
confidence: 99%
“…Similar observations were made earlier for the adsorption of fatty acids from solutions and vapor phase which showed that there is less adsorption on mica, gold, platinum and chromium than on nickel, iron and copper. 147 Both studies revealed that surfaces become contaminated at different rates and to different levels, as a result of adsorption driven by molecule-surface interactions. White also proposed that organics can be gathered from the air by adsorption onto oxidized metal surfaces and therefore used as filling media in storage compartments to maintain surface cleanness of lower energy specimens such as glass or mica.…”
Section: Contamination Of Hydrophilic Surfaces and Their Cleaningmentioning
confidence: 99%
“…Using this simplification the film thickness and mass density can be calculated. However, only a few studies have compared the mass density deduced from ellipsometry with that of radioisotope-labeled proteins or lipid depositions (7)(8)(9), i.e., calibrated the methods toward one another. In one recent study spontaneously adsorbed monolayers (up to 2 nm thick) of HSA were quantified by both RIA and null ellipsometry.…”
Section: Introductionmentioning
confidence: 99%
“…Since the contaminants adsorption is guided by the interaction between the molecule and the surface, the velocity and degree with which a surface is contaminated may differ [50,49]. For the evaluated experimentally cases, it is not known to what extent the hydrophilic tube wettability can be affected exactly by the continuous contact with the OP.…”
Section: Corroboration Of the Cfd Model Predictionsmentioning
confidence: 99%