1996
DOI: 10.1016/0305-4179(96)00035-6
|View full text |Cite
|
Sign up to set email alerts
|

A comparative study of silicone net dressing and paraffin gauze dressing in skin-grafted sites

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
19
0
3

Year Published

2005
2005
2018
2018

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 52 publications
(23 citation statements)
references
References 3 publications
0
19
0
3
Order By: Relevance
“…Pain severity is a commonly used outcome measure in the clinical evaluation of WCLs. 4,[14][15][16][17][18][19][20][21] In the present study, the main outcome was the frequency and percentage of patients experiencing a pain level <30 mm on a 100 mm VAS at day 3 (V2) immediately after the first allocated dressing had been removed. This pain parameter was selected based on previous research that demonstrates a likelihood of patients recording "moderate" or "severe" pain on a 4-point categorical pain scale scoring above 30 mm on a 100 mm VAS.…”
Section: Main Study Outcomesmentioning
confidence: 93%
See 1 more Smart Citation
“…Pain severity is a commonly used outcome measure in the clinical evaluation of WCLs. 4,[14][15][16][17][18][19][20][21] In the present study, the main outcome was the frequency and percentage of patients experiencing a pain level <30 mm on a 100 mm VAS at day 3 (V2) immediately after the first allocated dressing had been removed. This pain parameter was selected based on previous research that demonstrates a likelihood of patients recording "moderate" or "severe" pain on a 4-point categorical pain scale scoring above 30 mm on a 100 mm VAS.…”
Section: Main Study Outcomesmentioning
confidence: 93%
“…Pain severity is a commonly used outcome measure in the clinical evaluation of WCLs . In the present study, the main outcome was the frequency and percentage of patients experiencing a pain level <30 mm on a 100 mm VAS at day 3 (V2) immediately after the first allocated dressing had been removed.…”
Section: Methodsmentioning
confidence: 99%
“…По вязки с технологией Safetac* сводят к минимуму травматизацию тканей и боль при смене повязок. Перевязочные средства Tendra® продемонстриро вали свое преимущество, обеспечивая минималь ную травматизацию раны и окружающей рану ко жи, в сочетании с минимизацией болевого синд рома при смене повязок [4,9,12].…”
Section: сахарный диабетunclassified
“…Так как для адекватной работы повязки необходим плотный контакт с поверхностью, использование Mepitel ограничивается относительно ровными ана томическими областями. Эффективность Mepitel и Mepilex подтверждена целым рядом клинических исследований [2][3][4]7,[12][13][14]16].…”
Section: лечениеunclassified
“…Chang viscoelastic window concept adapted for low resin content silicone pressure sensitive adhesive (PSA) with differing amounts of isopropyl myristate (IPM) [34]. the wound care market by Dow Corning Corporation in the 1990s and similar materials are offered today by many silicone suppliers under a variety of brand names [36][37][38]. In a segment that was historically controlled primarily by acrylic adhesives, the tacky gel technology concept was disruptive by securing wound dressings while providing gentle adhesion upon removal.…”
Section: Silicone Soft Skin Adhesive: Description and Applicationsmentioning
confidence: 99%