2013
DOI: 10.1016/j.jcis.2013.02.030
|View full text |Cite
|
Sign up to set email alerts
|

A comparative study of submicron particle sizing platforms: Accuracy, precision and resolution analysis of polydisperse particle size distributions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

22
313
0
3

Year Published

2013
2013
2018
2018

Publication Types

Select...
5
5

Relationship

0
10

Authors

Journals

citations
Cited by 329 publications
(338 citation statements)
references
References 25 publications
22
313
0
3
Order By: Relevance
“…The mean NPs diameters measured by the Nanoparticle Tracking Analysis System were generally smaller in comparison with those observed by DLS ( Table 2). The comparatively large value reported for NM-300 by Nanoparticle Tracking Analysis System can be related to the limit of detection of the method, which is not reliable for nanoparticles typically below 30-50 nm depending on the NPs optical properties [27][28][29]. Results obtained for NM-300 size distribution by DLS were comparable with those previously observed [30] and indicate a polydispersity of the sample, and therefore an unreliable value of the size measured by DLS [31].…”
Section: Ag Nps Characterizationmentioning
confidence: 57%
“…The mean NPs diameters measured by the Nanoparticle Tracking Analysis System were generally smaller in comparison with those observed by DLS ( Table 2). The comparatively large value reported for NM-300 by Nanoparticle Tracking Analysis System can be related to the limit of detection of the method, which is not reliable for nanoparticles typically below 30-50 nm depending on the NPs optical properties [27][28][29]. Results obtained for NM-300 size distribution by DLS were comparable with those previously observed [30] and indicate a polydispersity of the sample, and therefore an unreliable value of the size measured by DLS [31].…”
Section: Ag Nps Characterizationmentioning
confidence: 57%
“…For this reason, care should be taken when choosing a measurement technique [45]. In cases of complex multimodal samples, TRPS can have a greater resolving power than PTA, where it is able to analyse all particles present in the sample [45]. …”
Section: Concentration Measurementsmentioning
confidence: 99%
“…Future work could use local ensembles to further extend this work to nonuniform bulk flows [31]. Gains in the accuracy of NTA for dilute, polydisperse suspensions are important because the reliability with which NTA measures polydisperse PSDs remains an open question [41,44]. For example, recent data characterizing patient placental extracellular vesicles using NanoSight R demonstrated that applied flow significantly affected results, but the study did not determine whether the difference was physical (issue with chamber design) or analytical (issue with algorithm) [45].…”
Section: Discussionmentioning
confidence: 99%