2011
DOI: 10.3155/1047-3289.61.3.260
|View full text |Cite
|
Sign up to set email alerts
|

A Comparative Study of the Performance of Passive Samplers

Abstract: Atmospheric concentrations of benzene, toluene, ethylbenzene, and xylenes (o-xylene and m,p-xylene) were assessed in the Tricity area (Gdań sk-Sopot-Gdynia, Poland) with the use of two types of passive samplers: permeation (homemade passive samplers) and diffusive (Radiello and Orsa 5). Samples were collected during 2008 at selected sites in the Tricity area at monitoring stations belonging to the agency of Regional Air Quality Monitoring Foundation. The field study was conducted to compare the performance of… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2011
2011
2023
2023

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 20 publications
(8 citation statements)
references
References 23 publications
0
8
0
Order By: Relevance
“…There are many techniques for the isolation and preconcentration of VOCs from air samples, among which the most commonly is a passive method (long-term monitoring) that works by molecular diffusion process and a dynamic method (short-term monitoring) based on a sorption tube [21]. European Standards EN 16,516: 2017 [19] and EN ISO 16,000-9: 2006 [20] indicate reference method for the determination of VOCs and volatile aldehydes emissions from construction products based on test chamber.…”
Section: Emission Testingmentioning
confidence: 99%
“…There are many techniques for the isolation and preconcentration of VOCs from air samples, among which the most commonly is a passive method (long-term monitoring) that works by molecular diffusion process and a dynamic method (short-term monitoring) based on a sorption tube [21]. European Standards EN 16,516: 2017 [19] and EN ISO 16,000-9: 2006 [20] indicate reference method for the determination of VOCs and volatile aldehydes emissions from construction products based on test chamber.…”
Section: Emission Testingmentioning
confidence: 99%
“…Detailed information about preparing chemical standards of BTEX compounds can be found elsewhere [15,44,45].…”
Section: Chemical Standardsmentioning
confidence: 99%
“…Further information on the calibration procedure can be found elsewhere [18] Quality control/quality assurance Quality assurance and quality control procedures included the analysis of field blanks and parallel duplicate samples. For field blanks, additional passive samplers were taken to nine monitoring stations and left unexposed during the exposure period (14 days).…”
Section: Chemical Standardsmentioning
confidence: 99%