A comparison between silicone‐free and silicone‐based emulsions: Technological features and in vivo evaluation

Abstract: Objective Nowadays, the use of silicones in cosmetic formulation is still controversial, given that “natural” or “biodegradable” components are preferred. Often, the exclusion and/or the discrimination of these excipients from cosmetic field are unmotivated because all things cannot be painted with the same brush. Hence, we want to bring to light and underline the advantages of including silicones in cosmetic emulsions, refuting and debunking some myths related to their use. Methods Silicone‐free and silicone‐… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 10 publications
(6 citation statements)
references
References 52 publications
0
6
0
Order By: Relevance
“…Before starting the analysis, the sample was placed into the instrument vial slot, where it was left to equilibrate at 37 ± 0.5 °C (operative temperature) for five minutes. The measurements were conducted for 3 h, during which time the integrated TurbiSoft software (Formulaction, L’Union, France) recorded alterations in delta-backscattering (ΔBS) and delta-transmission (ΔT) profiles as a function of time and vial height [ 48 ], ultimately determining the destabilization kinetic profile by measuring the Turbiscan stability index (TSI). TSI values were directly derived from a sophisticated formula by the software according to Equation (3), as previously reported [ 49 ]: where scan i (h) is the average of backscattering recorded at each time (i) of measurement, scan i−1 (h) is the average of backscattering for the i−1 time of measurement and H represents the sample height.…”
Section: Methodsmentioning
confidence: 99%
“…Before starting the analysis, the sample was placed into the instrument vial slot, where it was left to equilibrate at 37 ± 0.5 °C (operative temperature) for five minutes. The measurements were conducted for 3 h, during which time the integrated TurbiSoft software (Formulaction, L’Union, France) recorded alterations in delta-backscattering (ΔBS) and delta-transmission (ΔT) profiles as a function of time and vial height [ 48 ], ultimately determining the destabilization kinetic profile by measuring the Turbiscan stability index (TSI). TSI values were directly derived from a sophisticated formula by the software according to Equation (3), as previously reported [ 49 ]: where scan i (h) is the average of backscattering recorded at each time (i) of measurement, scan i−1 (h) is the average of backscattering for the i−1 time of measurement and H represents the sample height.…”
Section: Methodsmentioning
confidence: 99%
“…The same protocol was performed to prepare emulsions in the presence of natural extracts. The formulations were kept at rest for 24 h at room temperature to ensure a suitable equilibration of the emulsions, and then all characterization studies were carried out as described below [33].…”
Section: Preparation Of Proposed Face Creamsmentioning
confidence: 99%
“…Polysiloxanes are extensively applied in many fields, including the cosmetic industry, electronics, biomedicine, artificial muscles, etc. [ 1 , 2 , 3 , 4 , 5 , 6 , 7 ]. Such a diversity of applications is owing to the unique properties of polysiloxanes: a wide range of working temperatures, weather resistance, inertness, hydrophobicity, chemical stability, low dielectric permittivity, etc.…”
Section: Introductionmentioning
confidence: 99%