2007
DOI: 10.1016/j.jim.2006.07.027
|View full text |Cite
|
Sign up to set email alerts
|

A cost effective non-commercial ECL-solution for Western blot detections yielding strong signals and low background

Abstract: We compared several alternative ECL solutions for Western blot detection of endogenous proteins in whole cell lysates using inexpensive, commercially available reagents. Starting from an existing protocol based on p-coumaric acid (pCA) as enhancer, we found that the ECL solution containing 4-iodophenylboronic acid (4IPBA) generated strong specific signals and low background chemiluminescence. We optimised the luminol, 4IPBA and hydrogenperoxide concentrations of this 4IPBA-ECL solution. The optimised 4IPBA-ECL… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
166
0

Year Published

2008
2008
2019
2019

Publication Types

Select...
10

Relationship

2
8

Authors

Journals

citations
Cited by 225 publications
(166 citation statements)
references
References 15 publications
0
166
0
Order By: Relevance
“…Proteins were transferred from SDS-PAGE and blue native gels onto a PVDF membrane (EMD Millipore) via semi-dry Western blotting. Immunosignals were detected by enhanced chemiluminescence (97) and visualized on x-ray films (Medix XBU) or via the LAS3000 image reader (FujiFilm). …”
Section: Methodsmentioning
confidence: 99%
“…Proteins were transferred from SDS-PAGE and blue native gels onto a PVDF membrane (EMD Millipore) via semi-dry Western blotting. Immunosignals were detected by enhanced chemiluminescence (97) and visualized on x-ray films (Medix XBU) or via the LAS3000 image reader (FujiFilm). …”
Section: Methodsmentioning
confidence: 99%
“…After three washes in TBS-0.05% Tween, the membranes were incubated with the appropriate HRP-conjugated secondary Abs for 2 h at room temperature. After three further washes in TBS-0.05% Tween, the membranes were incubated with HRP substrate solution (22) and exposed to light-sensitive film for various times. Rac1-GTP levels were assessed according to the manufacturers' protocol (Millipore).…”
Section: Sds-page and Western Blottingmentioning
confidence: 99%
“…Signals were detected using an ECL solution containing 2.5 mM Luminol (SigmaAldrich: 123072), 2.6 mM hydrogenperoxide (SigmaAldrich: H1009), 100mM Tris-HCL/ pH8.8 (SigmaAldrich: T-1503) and 0.2 mM para-coumaric acid (SigmaAldrich: C9008). 60 Prior to reprobing, the blots were stripped in 2%SDS (Carl Roth: CN30.3), 100 mM b-mercaptoethanol (Carl Roth: 4227.3) in 62.5 mM Tris-HCl (pH6.7/ for 30 min at 70 C).…”
Section: Cloning and Expression Vectorsmentioning
confidence: 99%