2021
DOI: 10.1016/j.egyr.2021.01.083
|View full text |Cite
|
Sign up to set email alerts
|

A demand-response method to balance electric power-grids via HVAC systems using active energy-storage: Simulation and on-site experiment

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 23 publications
(5 citation statements)
references
References 24 publications
0
5
0
Order By: Relevance
“…The BESS is charged when there is excess energy available. The energy stored in the BESS (E s BESS ) is positive in the case of charging the BEES, and is calculated according to (19).…”
Section: Strategies For An Active User With a Pv Plant Onlymentioning
confidence: 99%
See 1 more Smart Citation
“…The BESS is charged when there is excess energy available. The energy stored in the BESS (E s BESS ) is positive in the case of charging the BEES, and is calculated according to (19).…”
Section: Strategies For An Active User With a Pv Plant Onlymentioning
confidence: 99%
“…Price-based programs are based on dynamic tariffs, where the prices of the tariff values change depending on the electric energy market circumstances and network conditions. Price-based programs based on time and power demand can be classified as the following [19]: time-of-use pricing, real-time pricing, and critical-peak pricing. In [20], a self-scheduling model for a HEMS is presented considering time-of-use pricing and real-time pricing, aiming to reduce the users' electric energy costs.…”
Section: Introductionmentioning
confidence: 99%
“…Furthermore, research endeavors have ventured into exploring the untapped potential of various building components and technologies, including PCM-enhanced building envelopes [63], hot water heat pumps [57], and energy storage systems [54,56,65,86]. These studies have yielded invaluable insight into the effectiveness of diverse strategies and their repercussions on energy consumption, cost mitigation, and peak load management.…”
Section: Key Findingsmentioning
confidence: 99%
“…Both the power supply side (Takahashi et al, 2017) and the energy storage side (Meng et al, 2021) can be directly connected to dispatch. Unlike the abovementioned subjects, the load side's minimum regulation unit is the user, which the LA must integrate to provide grid regulation capacity.…”
Section: Literature Reviewmentioning
confidence: 99%