2007
DOI: 10.1134/s0036024407010165
|View full text |Cite
|
Sign up to set email alerts
|

A desorption mass spectrometry study of the interaction of cinnamic acid with a silica surface

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
32
0

Year Published

2007
2007
2017
2017

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 27 publications
(34 citation statements)
references
References 3 publications
2
32
0
Order By: Relevance
“…The TPD MS experiments were performed on a MKH-7304A monopole mass-spectrometer (Sumy, Ukraine) with electron impact ionization adapted for thermodesorption measurements as described earlier [26,27]. A typical TPD MS test comprised placing the samples of 0.1-20 mg weight on the bottom of a molybdenum-quartz ampoule, its evacuating to $5 Â 10 À5 Pa at $20°C.…”
Section: Instruments and Proceduresmentioning
confidence: 99%
“…The TPD MS experiments were performed on a MKH-7304A monopole mass-spectrometer (Sumy, Ukraine) with electron impact ionization adapted for thermodesorption measurements as described earlier [26,27]. A typical TPD MS test comprised placing the samples of 0.1-20 mg weight on the bottom of a molybdenum-quartz ampoule, its evacuating to $5 Â 10 À5 Pa at $20°C.…”
Section: Instruments and Proceduresmentioning
confidence: 99%
“…The TPD MS experiments were performed on a MX-7304A monopole mass spectrometer (Sumy, Ukraine) with electron impact ionization adapted for thermodesorption measurements as described earlier [17,18]. A typical TPD MS test comprised placing the samples of 0.1-2 mg weight on the bottom of a molybdenumquartz ampoule, its evacuating to ∼5 × 10 −5 Pa at ∼20 • C and the sample heating at a rate of 0.15 • C/s up to ∼750 • C. The volatile pyrolysis products passed through a high-vacuum valve into the ionization chamber of the mass-spectrometer, where they were ionized and fragmented by electron impact.…”
Section: Mass Spectrometrymentioning
confidence: 99%
“…In the previous works [17,18] we have reported the TPD MS study of the cinnamic and ferulic acid interaction with fumed silica. Several decomposition pathways of these acids on silica surface were found.…”
Section: Introductionmentioning
confidence: 98%
“…[27] For example, some derivatives of another natural oxygen heterocycles γ -pyrones and chromones [28 -30] and biologically active substituted cinnamic acids have been lately studied. [31,32] Despite the importance of the gathered empirical evidence, the development of complex drugs demands more detailed information about the interactions in the adsorbed state, the structure of surface complexes and their mechanism of formation. Such information could be obtained from the analysis of TPD-MS data.…”
Section: Introductionmentioning
confidence: 99%
“…Such information could be obtained from the analysis of TPD-MS data. [31,32] Of special interest would be the application of this technique to the elucidation of the binding mechanisms of coumarins on the silica surface.…”
Section: Introductionmentioning
confidence: 99%