A Diagnostic Method for the Saturable Reactor Core Looseness Degree of Thyristor Converter Valves

Lin Zheng,
Xiaoguang Wei,
Tianshu Sun
et al.

Abstract: During the long-term operation of thyristor converter valves, the saturable reactor vibration (mainly caused by magnetostriction) will lead to core looseness faults. In order to accurately evaluate the fault degradation degree, this paper proposes a vibration signal recognition model for iron core looseness based on synchrosqueezed wavelet transforms and a convolutional neural network. Firstly, vibration experiments are conducted on saturable reactors to obtain signals under different core looseness degrees. T… Show more