2018
DOI: 10.15583/jpchrom.2017.023
|View full text |Cite
|
Sign up to set email alerts
|

A Direct Injection LC/ESI-MS/MS Analysis of Urinary Cyclophosphamide as an Anticancer Drug for Monitoring Occupational Exposure

Abstract: A highly sensitive and reliable analytical method that uses liquid chromatography/electrospray ionization tandem mass spectrometry coupled with a simple on-line solid-phase extraction was developed to monitor occupational exposure by measuring cyclophosphamide in the urine of medical staffs who handle this anticancer drug. The quantitation limit is 3 pg/mL with a signal-to-noise ratio of more than 10, and the measurement range is 3 pg/mL to 3 ng/mL. Using this method, trace levels of cyclophosphamide have been… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
10
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 8 publications
(13 citation statements)
references
References 9 publications
3
10
0
Order By: Relevance
“…Korany and co-workers, in 2022, investigated the protonated CP fragmentation by ESI–MS and quantum mechanics . In this work, they reported fragments observed earlier in the literature and presented theoretical calculations to reason the structures proposed, confirming previous propositions. , …”
Section: Introductionsupporting
confidence: 81%
See 3 more Smart Citations
“…Korany and co-workers, in 2022, investigated the protonated CP fragmentation by ESI–MS and quantum mechanics . In this work, they reported fragments observed earlier in the literature and presented theoretical calculations to reason the structures proposed, confirming previous propositions. , …”
Section: Introductionsupporting
confidence: 81%
“…As reported by Maekawa et al and Bai et al, the chlorine isotopic distribution allows the structural elucidation of these species. It was observed by mass selecting specific isotope distributions that the [CP + H] + species with two 35 Cl ( m / z 261) alone was the origin of both fragments.…”
Section: Resultsmentioning
confidence: 76%
See 2 more Smart Citations
“…Column switching was used as the LC system in this study. 26,27,29,54) After injection of the diluted sample, a 20 mmol/L ammonium acetate solution/ methanol (9 : 1, v/v) mixture was loaded onto an OASIS HLB column for pretreatment (2.1 mm i.d. × 20 mm, 5 µm, Waters, Milford, MA, U.S.A.).…”
Section: Methodsmentioning
confidence: 99%