A “dose on demand” Biomarker Generator for automated production of [18F]F− and [18F]FDG

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
29
1
1

Year Published

2015
2015
2020
2020

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 30 publications
(33 citation statements)
references
References 9 publications
2
29
1
1
Order By: Relevance
“…Several efforts are underway to develop integrated QC testing instruments that automatically perform and document all of the required tests and calibrations, e.g. QC-1 [19] (Munster, Germany), Trace-ability [20] (Culver City, CA USA), and ABT Molecular Imaging Inc. [21, 22] (Louisville, TN USA). While potentially alleviating the labor burden, these systems are still based on conventional, macroscale instruments linked into an integrated system along with a sample distribution mechanism.…”
Section: Introductionmentioning
confidence: 99%
“…Several efforts are underway to develop integrated QC testing instruments that automatically perform and document all of the required tests and calibrations, e.g. QC-1 [19] (Munster, Germany), Trace-ability [20] (Culver City, CA USA), and ABT Molecular Imaging Inc. [21, 22] (Louisville, TN USA). While potentially alleviating the labor burden, these systems are still based on conventional, macroscale instruments linked into an integrated system along with a sample distribution mechanism.…”
Section: Introductionmentioning
confidence: 99%
“…Chemie allowing the dose-on-demand preparation of these small molecules on site. [32] Scheme 3shows the automated synthesis of the 18 F-labeled hypoxia imaging positron emission tomography (PET) tracer [ 18 F]FAZA (9). In the first step, [ 18 F]fluoride was flushed from an ion exchange cartridge into the reaction vial containing potassium carbonate Kryptofix 2.2.2.…”
Section: Methodsmentioning
confidence: 99%
“…Zumindest die teilweise Automatisierung von optimierten Synthesen ist im industriellen Maßstab bereits weit verbreitet, und als wichtiger Grund dafürk ann der positive Einfluss der automatischen Herstellung auf die Skalierbarkeit gesehen werden. [27] [32] In Schema 3i st die automatische Synthese des 18 [33] Weitere Beispiele fürd ie automatisierte Synthese von radiomarkierten Verbindungen sind Pittsburgh compound-B ( 11 C-markiertes Derivat), [34] Paclitaxel ( 18 F-markiertes Derivat) [35] sowie andere 18 Fund 68 Ga-markierte Verbindungen. [36] Zusätzlich zu Sicherheitsrisiken, die mit bestimmten Chemikalien einhergehen, kçnnen auch extreme Bedingungen und exotherme Reaktionen speziell im großen Maßstab eine nicht zu unterschätzende Gefahrenquelle sein.…”
Section: Skalierbarkeitunclassified